SICK S3000 Addendum Operating Instructions

SICK S3000 Addendum Operating Instructions

Safety laser scanner
Hide thumbs Also See for S3000:

Advertisement

Quick Links

A D D E N D U M O P E R A T I N G I N S T R U C T I O N S
S3000 in a narrow aisle
Safety Laser Scanner
GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK S3000

  • Page 1 A D D E N D U M O P E R A T I N G I N S T R U C T I O N S S3000 in a narrow aisle Safety Laser Scanner...
  • Page 2: Tl59/2010

    This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Alteration or abridgement of the document is not permitted without the explicit written approval of the company SICK AG.
  • Page 3: Table Of Contents

    4.4.5 Example for protective field configuration for single-sided narrow aisle situation ...............13 Test object ......................15 Commissioning....................15 Checking the system...................15 Accessories......................15 8012793/TL59/2010-01-29 © SICK AG • Industrial Safety Systems • Germany • All rights reserved Subject to change without notice...
  • Page 4: About This Document

    This document is an original document. This addendum describes only the general conditions that must be observed on the usage of the S3000 in a narrow aisle. This addendum does not describe the properties and special features of the S3000 itself.
  • Page 5: Regulations To Be Observed

    S3000 in a narrow aisle Regulations to be observed Along with the regulations stated in the operating instructions for the S3000 and in this application description, the following documents from the responsible Berufsgenossenschaft (Großhandel and Lagerei) (German trade association —...
  • Page 6: Operating Conditions

    The S3000 type is a category 3 device for the protection of personnel in accordance with EN ISO 13 849F1 and SIL 2 in accordance with IEC 61 508/EN 61 508. The S3000 is suitable for use on industrial trucks in narrow aisles. Taking into account document 3 in chapter 2 “Regulations to be observed”...
  • Page 7: Installation And Commissioning

    150 mm. When driving forwards the lifting device (fork) must be raised sufficiently such that the Notes protective field on the S3000 is unoccupied. Here the work safety regulations BGV D27 §12, sections 2 and 3, are to be observed. 8012793/TL59/2010-01-29 ©...
  • Page 8: Operating Mode Of The S3000

    D 150 cm. S3000–Shelf – Time delayed by 2 s if the maximum distance from the middle of the S3000 to the front of the shelf on the left or right is 150 < D 250 cm.
  • Page 9: Required Protective Field Length

    All S3000 variants provide the required resolution of 70 mm at the max. protective field radius. As a result only the bottom cylindrical part of the test object is relevant.
  • Page 10 20 cm (see Tab. 1). The maximum permissible protective field lengths as a function of the distance from the middle of the S3000 to the front of the empty shelf are defined in Tab. 1 on page 11 and shown in Fig. 4.
  • Page 11: Required Protective Field Width

    0° for the left and right protective field width. If the S3000 is mounted off-centre on the industrial truck, the larger supplements S for the wider half protective field are to be used, however the protective field distances correspond to the width on the left and right.
  • Page 12 Tab. 1. During the configuration of the S3000 using the user software S3000 (see section 4.3 “Operating mode of the S3000” on page 8), the application variant “mobile” is to be set. If it is not possible to program a permissible corner point because the permissible...
  • Page 13: Example For Maximum Usable Protective Field Length And Stopping Distance

    300 < W 350 < W < 400 Depending on the distance from the middle of the S3000 to the front of the shelf, the supplement S is to be added to the necessary protective field length as per Tab. 1.
  • Page 14 = 60 cm S3000–Shelf – Distance on right from middle of S3000 to the right vehicle contour of 270 cm Required protective field width X – Left protective field width, as per section 4.4.2 and Tab. 1 on page 11: –...
  • Page 15: Test Object

    BGV D27 §39. Checking the system To ensure detection is reliable, the mounting of the S3000, the guide play and the braking action on the industrial truck are to be checked regularly.