Error
Description
09
Vacuum Contactor Coil Overload The contactor coil amperage was detected above 2.4 amps for more
10
Brush Contactor Coil Overload
11
Chemical Pump Overload
70
Corrupt Communication From
On-Board Battery Charger
Comments
than 5 seconds.
• Check for wiring problems on the coil circuit and repair wiring.
• Check resistance on the contactor coil. If the value is less than
50 Ω, replace the contactor.
The contactor coil amperage was detected above 2.4 amps for more
than 5 seconds.
• Check for wiring problems on the coil circuit and repair wiring.
• Check resistance on the solenoid coil. If the value is less than
45 Ω, replace the contactor.
The pump coil amperage was detected above 2.4 amps for more
than 5 seconds.
• Check for wiring problems on the motor circuit and repair wiring.
• If the actual current through the pump is high, replace the pump. It
is a solenoid driven diaphragm pump and a fluid blockage will not
increase amperage.
The Battery Charger did not properly repeat the charging profile
message back to the Main Machine Controller.
Control System
24