Glas Craft MH II User Manual page 7

Dispensing system
Hide thumbs Also See for MH II:
Table of Contents

Advertisement

1
MAIN POWER SWITCH
EMERGENCY STOP PUSH
2
BUTTON
3
AMMETER
HOSE TEMPERATURE
4
CONTROLLER
5
ON PUSH BUTTON
6
WHITE PILOT LIGHT
7
POLY PRESSURE GAUGE
8
ISO PRESSURE GAUGE
9
HYDRAULIC PRESSURE KNOB
10
HYDRAULIC PRESSURE GAUGE
11
ON PUSH BUTTON
ISO / POLY TEMPERATURE
12
CONTROLLER
OVER-PRESSURE RESET
13
BUTTONS
14
ON PUSH BUTTON
15
OFF PUSH BUTTON
16
COUNTER
17
RETRACT SWITCH
18
HYDRAULIC OIL FILL CAP
19
ISO / POLY DUMP VALVES
20
HOSE THERMOCOUPLE OUTLET
22850-XX MH System Console
Controls power and door; handle must point 1 to
energize power , handle must point to 0 to open control
box door. White pilot indicates when lighted, that the
main power is on.
To stop all functions, push down on red button. To reset,
turn handle on push button. All functions will remain off
until main power switch has been switched off and back
on
An instrument for measuring amperes to the primary
side of the hose's transformer.
Controls temperature of liquid inside the heated hoses.
To set desired temperature, press the up or down button
until you reach desired temperature From this point, the
temperature control is completely automatic.
Powers the controller. It requires 10 seconds for the
Controller to respond.
Indicates power on.
Indicates material pressure.
Indicates material pressure.
Increases or decreases hydraulic pressure. Turn
clockwise to increase pressure. Turn counter-clockwise
to decrease pressure.
Indicates hydraulic pump pressure
Powers the controller. It requires 10 seconds for the
Controller to respond.
Controls temperature of liquid inside ISO heater. To set
desired temperature, press the up or down button until
you reach desired temperature. From this point, the
temperature control is completely automatic.
When over-pressure is detected, the hydraulic power
pack will be shut down, and will remain off until
pressure is reduced and the push button is reset.
Power On To the hydraulic power pack.
Power Off to the hydraulic power pack.
Counts pumps cycles.
.042 GPC / .021 GPS
Retracts pumps to the full down stroke position to
protect pump shafts.
Remove cap to fill tank with recommended hydraulic oil.
Relieves pressure and material from ISO & POLY side.
Power outlet for hose thermocouple.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents