14.
Turn purge air and material valves ON at the gun.
ON
15.
If one side registers considerably more
pressure than the other side, go to the high pres-
sure side and bleed off some pressure by slightly
opening the manual material valve on the side
block over the container. Bleed pressure until both
sides are approximately the same pressure.
WARNING
Material will dispense at high pressure. follow all
safety precautions
Operation
16.
NOTE
The Emergency Stop Switch is located on the top right side
of the Box Panel, when depressed, it will shut down the pow-
er and activate the Air Dump Valve. To reset, turn handle on
push button.
17.
The system incorporates monitors for high pressure
monitoring. These monitoring devices will prevent the
system from continued operation if high pressure
situations develop.
There are pressure sensors located on each proportioning
pump. The high pressure sensor is located at the outbound
of the fluid section.
The high pressure monitoring sensor will engage if fluid pres-
sure increases above 3200 psi.
If a high pressure situation develops, the sensor will detect
this and immediately engage the hold-in circuit.
OFF
This will disengage power to the machine and it will stop
cycling. It will also turn the heater off.
On the control box panel, there are two yellow lighted push
buttons marked over pressure. One of these push buttons
will be illuminated after the monitoring sensor engages, indi-
cating where the problem is located (ISO or Poly).
46
Relieve any excess pressure by triggering the gun.
The system is now ready for operation.

Over Pressure System Protection

Over Pressure Resets