Installation
5.
Install thermocouple at tee fitting.
a. Feed 12' line through hose.
b. Nut & Ferrules will lock into fitting.
c. Tighten nut 1-1/4 turns past finger tight.
d. Plug thermocouple into control box.
Note: When replacing thermocouple use kit p/n: 21214-01.
TO AIR
MANIFOLD
6. a.
Connect hose assembly to the front of the unit. The
fittings are sized differently and will attach only one
way. (match like sized fittings).
b. Connect twist-lock plugs. (see hose installation)
7.
Connect supplied trigger air line to the
air line on the hose assembly.
8.
Connect whip hose p/n: 18006-00 to hose assembly,
pn: 22023-01.
9.
Connect jumper p/n: 22094-00 to plugs on hose
assembly to complete circuit.
Note:
Jumper not needed with 18006-01 heated whip hose.
10.
a. Connect whip hose assembly to gun. The fittings
are sized differently and will attach only one way.
b. Connect the air hose to gun.
11.
The hose connections between the unit and gun
should now be complete.
ALL FITTINGS SHOULD NOW BE TIGHT
CAUTION
Hose assemblies are constructed of durable, rugged
materials, however they are not indestructible. To provide
precisely controlled heated material, the hoses have electri-
cal wiring wrapped between layers. Avoid dragging hoses
over or around sharp, abrasive edges and corners. Exercis-
ing caution and common sense will give long, and reliable
service from the hoses.