Left Crankcase Cover Removal
Remove left
footrest.
Drain out the engine oil and coolant, and then remove
coolant hoses.
Remove water pump (2 bolts).
Remove 15 bolts from the left crankcase cover.
Remove the left crankcase cover.
Remove dowel pin and gasket.

A.C.G. Set Removal

Remove 3 mounted screws from pulse generator and
then remove it.
Remove 3 screws from left crankcase cover and then
remove generator coil set.
Left Cover Bearing
Inspection
Rotate the bearing with finger to check if the bearing
rotation is in smooth and silent.
Check if the bearing outer parts are closed and fixed.
Replace it if necessary.
Remove the bearing.