Diagnostics and troubleshooting

1127412619
8.9.1

Notifications via network

1127414155
1127415691
8.9.1.1

Explicit Message Connection

Device Status is available by reading Class 1, instance 1, attribute 5. Vendor specific interface
for alarms and diagnostic for Explicit Message Connections is defined as follows:
Presence of process alarm can be detected by reading class 29, instance 1, attribute 5 and
class 30, instance 1, attribute 5. The module mode (Run or another state) has to be checked,
because the alarm bit is set to 0 = OK every time the module is not in Run mode.
The module mode can be detected by reading class 120 Instance 5 Attribute 1.
The presence of module diagnostic events can be detected by reading class 120 Instance 6 At-
tribute 1.
Detailed reasons for process alarms and system diagnostic events can be found out by reading
all 60 attributes of Class 120 Instance 3 which contains the dedicated system status bytes.
1127417227
8.9.1.2

Implicit Message Connection

If assembly instance 57 is used, Bit 6 and 7 of Byte 66 signal a process alarm when set.
If assembly instance 167 is used, Bit 6 and 7 of Byte 66 signal a process alarm when set. Bit 5
signals diagnostic events or process alarms when set.
Event details can be queried by Explicit Message requests as described here:
saging [ch. 8.6.1, p. 106]
8.9.2

LED States

1127418251
1127419787
8.9.2.1

MS (Module Status)

The SP-COP2-ENI module possesses a two-color (red/green) LED with the designation MS.
This is the Module Status Indicator.
The Module Status Indicator is
device has not been configured. It
green/red
The Module Status Indicator
a serious, eliminable error. A faulty project file or one which does not match the hardware is
classified as a serious, eliminable error. The display
device has detected a serious, non-eliminable error and there is a Critical Fault.
Table 63: MS-LED state (Selection)
Project file
Doesn't matter
Deleted
Invalid
Valid
Valid
Valid
Valid
1127421323
Wieland Electric GmbH | BA000970 | 11/2016 (Rev. F)
dark
turns green
if the device is performing a switch-on test.
flashes red
System mode
Switch on
Init
Init
Idle mode
Run
Run
Critical error
, if no power supply is connected. It
if the device is running correctly. It
if EtherNet/IP is activated and the device has detected
turns red
Ext. Error
MS-LED state
Doesn't matter
Green -> Red
Doesn't matter
Flashing green
Doesn't matter
Flashing red
Doesn't matter
Flashing green
No
Turns green
Yes
Turns green/red or flashes red
Doesn't matter
Turns red
EtherNet/IP gateway
Explicit Mes-
flashes green
if the
flashes
if EtherNet/IP is activated and the
109

Advertisement

Table of Contents
loading

Table of Contents