Download Print this page

Philips DVDR730/0x Service Manual page 69

Dvd-video recorder

Advertisement

Nucleus Name
DS_SYS_SettingsDoubleCheck
Nucleus Number
1233
Description
This nucleus sets the HW-Id in the HW-diversity string
User Input
-
Example
DS:> 1232
Enter the new HW ID of the digital board (Currently equals 21)
Enter a value between 0 and 99:
> 22
The HW ID will be set to: 22. Is that correct? ([Y/N]):y
123200:
Test OK @
DS:> 1232
Enter the new HW ID of the digital board (Currently equals 22)
Enter a value between 0 and 99:
>
The HW ID will be set to: 0. Is that correct? ([Y/N]):N
123202: Setting the HW ID was aborted by the user.
Error @
DS:> 1232 99
123200:
Test OK @
Electronic Program Guide Board (EPGB)
Nucleus Name
DS_EPGB_VersionGet
Nucleus Number
1300
Description
Returns the version of the EPG board.
User Input
None
Example
DS:> 1300
130000:
Version : 6.1.9
Test OK @
PCMCIA INTERFACE (PCMCIA)
Nucleus Name
DS_PCMCIA_Reset
Nucleus Number
1400
Description
Reset the PCMCIA device by sending a reset command through IDE
Example
DS:> 1400
140000:
Test OK @
Nucleus Name
DS_PCMCIA_Inquiry
Nucleus Number
1401
Description
Get the vendor- and product identification and the product revision level of the media
in the slot.
Example
DS:> 1401
140100:
Test OK @
Nucleus Name
DS_PCMCIA_WriteRead
Nucleus Number
1402
Description
Perform a Write Read test to a random sector on the inserted medium in the
PCMCIA device and check if the data read is equal to the data written.
Example
DS:> 1402
140200:
Test OK @
Nucleus Name
DS_PCMCIA_Diagnostics
Nucleus Number
1403
Description
Shall perform the internal diagnostic tests implemented by the PCMCIA slot. The
electronics of the PCMCIA slot are tested here, not the inserted medium.
Example
DS:> 1403
140300:
Test OK @
Diagnostic Software
<HW-ID> - The hardware ID to set
-No input - The user will be asked for the ID
DVDR730/0x
5.
EN 69