5. Diagnostic Software
Due to the complexity of the DVD recorder, the time to find a
defect in the recorder can become long. To reduce this time,
the recorder has been equipped with Diagnostic and Service
software (DS). The DS offers functionality to diagnose the
DVDR hardware and tests the following:
Interconnections between components
Accessibility of components
Functionality of the audio and video paths
This functionality can be accessed via several interfaces:
1. End user/Dealer script interface
2. Command Interface
5.1
End User/Dealer Script Interface
5.1.1
Description
The End user/Dealer script interface gives a diagnosis on a
stand alone DVD recorder. During this mode, a number of
hardware tests (nuclei) are automatically executed to check if
the recorder is faulty. The diagnosis is simply a "fail" or "pass"
message. If the message "FAIL" appears on the display, there
is apparently a failure in the recorder. If the message "PASS"
appears, the nuclei in this mode have been executed
successfully. There can be still a failure in the recorder
because the nuclei in this mode don't cover the complete
functionality of the recorder.
Included tests:
1.DS_ANAB_COMMUNICATIONECHO_NUC

2.DS_DCB_COMMUNICATIONECHO_NUC 3.

DS_BROM_COMMUNICATION_NUC
DS_SYS_SETTINGSDISPLAY_NUC
DS_CHR_DEVTYPEGET_NUC6. DS_CHR_INT_PIC_NUC7.
DS_CHR_DMA_NUC8. DS_BROM_WRITEREAD_NUC9.
DS_NVRAM_COMMUNICATION_NUC10.
DS_NVRAM_WRITEREAD_NUC11.
DS_SDRAM_WRITEREADFAST_NUC12.
DS_FLASH_WRITEREAD_NUC13.DS_FLASH_CHECKSUMPROGRAM_
NUC14.DS_SYS_HARDWAREVERSIONGET_NUC15.
DS_VIP_DEVTYPEGET_NUC16. DS_VIP_COMMUNICATION_NUC17.
DS_DVIO_LINKDEVTYPEGET_NUC18.
DS_DVIO_PHYDEVTYPEGET_NUC19.
DS_DVIO_LINKCOMMUNICATION_NUC20.
DS_DVIO_PHYCOMMUNICATION_NUC21.DS_PSCAN_COMMUNICATI
ONDENC_NUC22.DS_PSCAN_COMMUNICATIONDEINTERLACER_NU
C23.
DS_BE_COMMUNICATIONECHO_NUC24.DS_ANAB_COMMUNICATIO
NIICNVRAM_NUC25.DS_ANAB_COMMUNICATIONIICTUNER_NUC26.D
S_ANAB_COMMUNICATIONIICSOUNDPROCESSOR_NUC27.DS_ANA
B_COMMUNICATIONIICAVSELECTOR_NUC28.
DS_ANAB_CHECKSUMPROGRAM_NUC
Diagnostic Software
5.1.2
Structure
Unplug the power cord
Hold key <PLAY> pressed
while you plug the recorder
During the test, the display shows
the currently run test
SET O.K.?
YES
The End use/Dealer script executes all diagnostic nuclei that
do not need any user interaction and are meaningful on a
standalone DVD recorder.
5.1.3
Contents
4.
5.
DVDR730/0x
5.
NO
To exit DEALER SCRIPT, unplug the power cord
Figure 5-1