Download Print this page

Philips DVDR730/0x Service Manual page 53

Dvd-video recorder

Advertisement

User Input
None
Example
DS:> 905
090500:
Test OK @
Nucleus Name
DS_BE_WriteReadDvdRw
Nucleus Number
906
Description
Write data to and read data from a DVD+RW disc through the basic engine for verification
of the writing
User Input
None
Example
DS:> 906
090600: Testing on sector 0x5dbe0: OK
Test OK @
Nucleus Name
DS_BE_WriteReadDvdR
Nucleus Number
907
Description
Write data to and read data from a DVD+R disc through the basic engine for verification of
the writing
User Input
None
Example
DS:> 907
090700: Testing on sector 0x36210: OK
Test OK @
Nucleus Name
DS_BE_StatisticalInformationGet
Nucleus Number
908
Description
Retrieve the statistical information from the basic engine
User Input
None
Example
DS:> 908
Total time the power power on (HR:MIN) 0: 0h
Total time of reading CDROM discs (HR:MIN) 0: 0h
Total time of reading high DVD SL discs (HR:MIN) 0: 0h
Total time of reading other DVD SL discs (HR:MIN) 0: 0h
Total time of reading high DVD DL siscs (HR:MIN) 0: 0h
Total time of reading other DVD DL discs (HR:MIN) 0: 0h
Total time of reading high DVD+R discs (HR:MIN) 0: 0h
Total time of reading other DVD+R discs (HR:MIN) 0: 0h
Total time of reading high DVD+RW discs (HR:MIN) 0: 0h
Total time of reading other DVD+RW discs (HR:MIN) 1: 0h
Total time of writing DVD+R discs in 2HRS mode (HR:MIN) 0: 0h
Total time of writing DVD+R discs in 4HRS mode (HR:MIN) 0: 0h
Total time of writing DVD+R discs in 6HRS mode (HR:MIN) 0: 2h
Total time of writing DVD+RW discs in 2HRS mode (HR:MIN) 0: 0h
Total time of writing DVD+RW discs in 4HRS mode (HR:MIN) 0: 3h
Total time of writing DVD+RW discs in 6HRS mode (HR:MIN) 0: 0h
090800:
Test OK @
Nucleus Name
DS_BE_StatisticalInformationReSet
Nucleus Number
909
Description
Reset the statistical information in the basic engine
User Input
None
Example
DS:> 909
090900:
Test OK @
Nucleus Name
DS_BE_ErrorLogGet
Nucleus Number
910
Description
Get the error log from the basic engine
User Input
None
Example
DS:> 910
Momentary errors (0-9): 0x21 0x00 0x00 0x20 0x00 0x00 0x00 0x00 0x00 0x00
Cumulative errors (1-9): 0x00 0x80 0x20 0x00 0x00 0x00 0x00 0x00 0x00
Software fatal assert : 256 cpowermanager.cpp
091000:
Test OK @
Diagnostic Software
DVDR730/0x
5.
EN 53

Advertisement

loading