332 Terminal 2, analog/digital input
(DIGITAL INPUT 2)
333 Terminal 3, digital input
(DIGITAL INPUT 3)
334 Terminal 4, digital input
(DIGITAL INPUT 4)
335 Terminal 5, digital input
(DIGITAL INPUT 5)
Parameter
Digital input on terminal no.
Settings:
No function
Reset
Coasting stop, inverse
Reset and coasting stop, inverse (RESET & COAST INV.)
Quick-stop, inverse
DC-braking, inverse
Stop inverse
Start
Latched start
Reversing
Start reversing
Start clockwise, on
Start counter-clockwise, on
Jog
Freeze reference
Freeze output
Speed up
Speed down
Selection of Setup
Catch-up
Slow-down
Preset reference
Preset reference, on
Precise stop, inverse
Pulse reference
Pulse feedback
Analog reference
Analog feedback
Reset and start
Description of choice:
No function
No function
No function
No function is selected if the FCM 300 is not to
No function
react to signals transmitted to the terminal.
Reset
Reset
Reset resets the FCM 300 after an alarm; however,
Reset
Reset
not all alarms can be reset without disconnecting
from AC Line.
Coasting stop, inverse
Coasting stop, inverse
Coasting stop, inverse is used for making the FCM
Coasting stop, inverse
Coasting stop, inverse
300 run freely to stop. Logic '0' leads to coasting
stop.
= General factory setting - also applying to spare part unit, H H H H H = HVAC setting, I I I I I = Industrial setting, ( ) = parameter
window text. [ ] = value for use in communication via serial communication port
MG.03.B6.2G - VLT is a registered Danfoss trademark
FCM 300 Series
In parameters 332-335 it is possible to choose
between the different possible functions related to
the inputs on terminals 2-5. The function options are
shown in the table below.
(NO OPERATION)
(RESET)
(MOTOR COAST INVERSE)
(QUICK STOP INVERSE)
(DC-BRAKE INVERSE)
(STOP INVERSE)
(START)
(LATCHED START)
(REVERSING)
(START REVERSING)
(ENABLE FORWARD)
(ENABLE REVERSE)
(JOGGING)
(FREEZE REFERENCE)
(FREEZE OUTPUT)
(SPEED UP)
(SPEED DOWN)
(SETUP SELECT)
(CATCH UP)
(SLOW DOWN)
(PRESET REF.)
(PRESET REF. ON)
(PRECISE STOP)
(PULSE REFERENCE)
(PULSE FEEDBACK)
(REFERENCE)
(FEEDBACK)
(RESET AND START)
Reset and coasting stop, inverse, is used for
Reset and coasting stop, inverse
Reset and coasting stop, inverse
Reset and coasting stop, inverse
Reset and coasting stop, inverse
activating coasting stop at the same time as reset.
Logic '0' leads to coasting stop and reset.
Quick-stop, inverse is used for stopping the motor
Quick-stop, inverse
Quick-stop, inverse
Quick-stop, inverse
Quick-stop, inverse
in accordance with the quick-stop ramp (set in
parameter 212).
Logic '0' leads to a quick-stop.
Function:
332
333
2
3
[0]
[0]
[1]
[1]
[2]
[2]
[3]
[3]
[4]
[4]
[5]
[5]
[6]
[6]
[7]
[7]
[8]
[8]
[9]
[9]
[10]
[10]
[11]
[11]
[12]
[12]
[13]
[13]
[14]
[14]
[15]
[15]
[16]
[16]
[17]
[17]
[18]
[18]
[19]
[19]
[20]
[20]
[21]
[21]
[22]
[22]
[24]
[25]
[30]
[31]
[32]
[32]
334
335
4
5
[0]
[0]
[1]
[1]
[2]
[2]
[3]
[3]
[4]
[4]
[5]
[5]
[6]
[6]
[7]
[7]
[8]
[8]
[9]
[9]
[10]
[10]
[11]
[11]
[12]
[12]
[13]
[13]
[14]
[14]
[15]
[15]
[16]
[16]
[17]
[17]
[18]
[18]
[19]
[19]
[20]
[20]
[21]
[21]
[22]
[22]
[23]
[32]
[32]
11-3