Danfoss FCM305 56 Instruction Manual page 52

Vlt drivemotor fcm 300 series
Table of Contents

Advertisement

Description of choice:
There is a choice of 24 different data values, see
parameter 009.
011 Display line 1.2 (DISPLAY LINE 1.2)
Value:
Motor current [A]
See parameter 009
Function:
This parameter enables a choice of the second of
the three data values to be shown on the display,
line 1, position 2.
For Display read-outs, press the [DISPLAY/STATUS]
button.
Description of choice:
There is a choice of 24 different data values, see
parameter 009.
012 Display line 1.3 (DISPLAY LINE 1.3)
Value:
Power [HP]
H,I
Power [kW]
See parameter 009
Function:
This parameter enables a choice of the third of the
three data values to be shown on the display, line 1,
position 3.
Display read-outs are made by pressing the
[DISPLAY/STATUS] button.
Description of choice:
There is a choice of 24 different data values, see
parameter 009.
013 Local Control/Configuration as
parameter 100 (LOCAL CTRL/CONFIG.)
Value:
Local not active (DISABLE)
LCP control and open loop.
(LCP CTRL/OPEN LOOP)
LCP digital control and open loop.
(LCP+DIG CTRL/OP.LOOP)
= General factory setting - also applying to spare part unit, H H H H H = HVAC setting, I I I I I = Industrial setting,
( ) = display text [ ] = value for use in communication via serial communication
8-6
FCM 300 Series
LCP control/as parameter 100.
(LCP CTRL/AS P100)
LCP digital control/as parameter 100.
(LCP+DIG CTRL/AS P100)
Function:
This is where the desired function is to be selected if
Local control has been chosen in parameter 002.
[6]
See also the description of parameter 100.
Description of choice:
If Local not active [0] is selected, a possible setting
of Local reference via parameter 003 is blocked.
It is only possible to change to Local not active [0]
from one of the other setting options in parameter
013, when the FCM 300 has been set to Remote
control [0] in parameter 002.
LCP control and open loop [1] is used when the
speed is to be adjustable (in Hz) via parameter 003,
when the FCM 300 has been set to Local control [1]
in parameter 002.
If parameter 100 has not been set to Speed
regulation open loop [0], switch to Speed regulation
[9]
open loop [0].
[8]
LCP digital control and open loop [2] functions as
LCP control and open loop [1], the only difference
being that when parameter 002 has been set to
Local operation [1], the motor is controlled via the
digital inputs.
LCP control/as parameter 100 [3] is selected if the
reference is to be set via parameter 003.
LCP digital control/as parameter 100 [4] functions as
LCP control/as parameter 100 [3], although, when
parameter 002 has been set to Local operation [1],
the motor may be controlled via the digital inputs.
NOTE!
Shift from Remote control to LCP digital control and
open loop:
The present motor frequency and direction of
[0]
rotation must be maintained. If the present direction
of rotation does not correspond to the reversing
[1]
signal (negative reference), the motor frequency f
will be set at 0 Hz.
[2]
MG.03.B6.2G - VLT is a registered Danfoss trademark
[3]
[4]
M