Danfoss FCM305 56 Instruction Manual page 123

Vlt drivemotor fcm 300 series
Table of Contents

Advertisement

Standard Parameter Settings
Function
Preset reference 1
Preset reference 2
Catch up/slow down value
Current limit for motor mode
Frequency bypass, bandwidth
Frequency bypass 1
Frequency bypass 2
Time out
Function after time out
P
ulse reference/feedback, max. freq.
Terminal 1, analog input current
Terminal 2, digital input
Terminal 3, digital input
Terminal 4, digital input
Terminal 5, digital input
Terminal 1, min. scaling
Terminal 1, max. scaling
Terminal 2, min. scaling
Terminal 2, max. scaling
Output functions
Brake function
Reset function
Switching frequency
Variable switching frequency
Overmodulation function
Minimum feedback
Maximum feedback
Reference/feedback unit
Process PID normal/inverse ctrl.
Process PID anti windup
Process PID start frequency
Process PID proportional gain
Process PID integral time
Process PID differentation time
Process PID different. gain limit
Process PID lowpass filter time
Flying start
Switching pattern
Bus address
Baudrate
Coasting
Quick-stop
DC-brake
Start
Reversing
Selection of setup
Selection of speed
Bus jog 1
Bus jog 2
Telegram profile
Bus time interval
Bus time interval function
MG.03.B6.2G - VLT is a registered Danfoss trademark
FCM 300 Series
Range/number
of settings
-100.00 % - +100.00 %
-100.00 % - +100.00 %
0.00 - 100.00 %
Min.- max. limit in % of I
0 (off) - 100 %
0.0 - 132 Hz
0.0 - 132 Hz
1 -99 sec.
Off/Stop and trip
100 - 70000 Hz
3
25
25
24
23
0.0 - 20.0 mA
0.0 - 20.0 mA
0.0 - 10.0 V
0.0 - 10.0 V
21
Off/AC braking
11
1.5 - 14.0 kHz
3
Off/On
-100000 - FB
HIGH
FB
- 100,000
LOW
42
Normal/inverse
Disable/Enable
f
- f
MIN
MAX
0.00 (off) - 10.00
0.01 - 9999 sec. (off)
0.00 (off) - 10.00 sec.
5 -50
0.1 - 10.00 sec.
4
2
1 - 126
300 - 9600 Baud/6
4
4
4
4
4
4
4
0.0 - f
MAX
0.0 - f
MAX
Profidrive/FC Drive
6
Factory setting
0.00 %
0.00 %
0.00 %
Max. limit
RATED
0 %
0.0 Hz
0.0 Hz
10 sec.
Off
5000 Hz
No operation
Reference
Reset
Start
Jog
0.0 mA
20.0 mA
0.0 V
10.0 V
No operation
Off
Manual reset
Unit dependent
Temp. dep. sw. freq.
On
0
1500
%
Normal
Enable
f
MIN
0.01
9999 sec.
0.00 sec.
5
0.1 sec.
Disable
SFAVM
1
9600 Baud
Logic or
Logic or
Logic or
Logic or
Logic or
Logic or
Logic or
10.0 Hz
10.0 Hz
FC Drive
1 sec.
Off
Parameter No.
Parameter 215
Parameter 216
Parameter 219
Parameter 221
Parameter 229
Parameter 230
Parameter 231
Parameter 317
Parameter 318
Parameter 327
Parameter 331
Parameter 332
Parameter 333
Parameter 334
Parameter 335
Parameter 336
Parameter 337
Parameter 338
Parameter 339
Parameter 340
Parameter 400
Parameter 405
Parameter 411
Parameter 412
Parameter 413
Parameter 414
Parameter 415
Parameter 416
Parameter 437
Parameter 438
Parameter 439
Parameter 440
Parameter 441
Parameter 442
Parameter 443
Parameter 444
Parameter 445
Parameter 446
Parameter 500
Parameter 501
Parameter 502
Parameter 503
Parameter 504
Parameter 505
Parameter 506
Parameter 507
Parameter 508
Parameter 509
Parameter 510
Parameter 512
Parameter 513
Parameter 514
19-3