Replacement Of 512 With 512C; 512C/512 Terminal Differences - Parker 512C Series Technical Manual

Hide thumbs Also See for 512C Series:
Table of Contents

Advertisement

R
EPLACEMENT OF

512C/512 Terminal Differences

TERMINAL
T1
Tacho Feedback
T2
Not Connected
T3
Speed Meter Output
T4
Minimum Speed
T5
Run
T6
Current Meter Output
T7
Torque/Current Limit
T8
0V Common
T9
Setpoint Ramp O/P
T10
Aux. Speed Setpoint
T11
0V Common
T12
Total Setpoint O/P
T13
Setpoint Ramp I/P
T14
+10V Reference
T15
Stall Reset.
T16
-10V Reference.
T17
Not Connected. *
T18
Not Connected. *
T19
Health Output
T20
Not Connected*
T21
Not Connected*
T22
Not Connected*
Zero Speed Output /
T23
Zero Setpoint Output
T24
Not Connected*
* Relays must be provided externally.
512C Series Converter
512
512C
Tacho Feedback
Not Connected
Speed Meter Output
Minimum Speed
Run
Current Meter Output
Torque/Current Limit
0V Common
Setpoint Ramp O/P
Aux. Speed Setpoint
0V Common
+12V
Setpoint Ramp I/P
+10V Reference
Stall Reset
-12V
Not Connected
Health Relay. N/C
Health Relay. Co
Health Relay. N/O
Not Connected
Zero Speed Relay. N/C
Zero Speed Relay. Co
Zero Speed Relay. N/O
www.comoso.com

Replacement of 512 with 512C

512C
WITH
512
Active High on 512C
Rescaled to be Normalised to
Setpoint Ramp I/P.
Undesirable to Provide access to
PS Rails.
Total Setpoint Output is a useful
alternative.
Signal Level Revised.
Undesirable to provide access
to PS Rails.
-10V Reference useful
alternative.
Relay removed.
Relay Removed.
Transistor O/P.
Relay removed.
Relay removed.
Relay Removed.
Transistor O/P.
Relay removed.
9-1
COMMENTS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents