Setting-Up & Commissioning

Option Switches

Speed Feedback Scaling

Table 4.1 Full speed tachogenerator/armature feedback voltage.
Example:
(a)
(b)
Note: It is necessary to set these switches for both tachogenerator and armature voltage
feedback.

Speed Feedback Source

Zero Output Source

Current Scaling

Table 4.2 Current Calibration
Example:
Option 1
Option 2
512C Series Converter
SW1
SW2
OFF
ON
ON
ON
OFF
OFF
ON
OFF
Customer wishes to run motor at 1500rpm with a 60V/1000rpm tachogenerator.
Feedback voltage = 90V
From Table 4.1 set SW1 OFF SW2 OFF adjust P7 to give desired speed.
Customer wishes to run motor at 2000rpm with 320V armature.
Feedback voltage = 320V
From Table 4.1 set SW1 ON SW2 OFF adjust P7 to give desired speed.
SW3
(OFF) Tachogenerator
SW3
(ON) Armature Voltage
SW4
(OFF) Zero Output
SW4
(ON) Zero Output
SW5
SW6
SW7
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
Customer wishes to run 14 Amp Motor.
Using 512/16 - From table 4.2 set SW7 ON, SW6 ON, SW5 OFF Ia = 14 Amp
Using 512/32 From table 4.2 set SW7 OFF, SW6 ON, SW5 ON - Ical = 16 Amp
Turn down I Limit (P4) to give 14 Amps
www.comoso.com
Operating the Converter
FEEDBACK VOLTAGE
10 - 25V
USE P7 TO TRIM
25 - 75V
MAXIMUM SPEED
75 - 125V
TO REQUIRED
125 - 325V
VALUE
Controller uses Tachogenerator Feedback
for Speed Control.
Controller uses Armature Voltage
Feedback for Speed Control.
Zero Setpoint Output
Zero Speed Output
FULL LOAD CURRENT CONTROLLER OPTION
04
08
½A
1A *
1A
2A *
1½A
3A *
2A
4A *
2½A
5A
3A
6A
3½A
7A
4A
8A
( * see note on next page )
4-2
16
32
2A *
4A *
4A *
8A *
6A *
12A *
8A *
16A *
10A
20A
12A
24A
14A
28A
16A
32A

Hide quick links: