Restoring Windows 10 Iot Enterprise Ltsb 2016; Windows 10 Iot Enterprise Ltsb 2016 Basic Functions - Dell Edge Gateway 3003 Installation And Operation Manual

Hide thumbs Also See for Edge Gateway 3003:
Table of Contents

Advertisement

Restoring Windows 10 IoT Enterprise LTSB 2016

CAUTION: These steps will delete all the data on your Edge Gateway.
You can restore Windows 10 IoT Enterprise LTSB 2016 by using a USB flash drive.
Prerequisites
Create the recovery USB flash drive. For more information, see
Procedure
1.
Connect the recovery USB flash drive to the Edge Gateway.
2.
Power on the Edge Gateway.
The Edge Gateway will automatically boot from the USB recovery flash drive and restore Windows back to the factory image.
Restoration takes about 25 minutes to complete and a confirmation log file is stored on the USB flash drive. Once restoration is
complete, the system will power off.
NOTE: The confirmation log file is named

Windows 10 IOT Enterprise LTSB 2016 basic functions

BIOS update
Download BIOS updates for the Edge Gateway from www.dell.com/support. The download includes an executable file that may be run
from the local machine. For more information about updating the BIOS, see
Watchdog Timer
The Watchdog Timer for Windows 10 IoT Enterprise LTSB 2016 is controlled through the BIOS setting.
Enter the BIOS during boot by pressing F2.
The Watchdog Timer is enabled and disabled under the BIOS setting Watchdog Timer.
NOTE: For more information about BIOS settings on the Edge Gateway, see
Cloud LED
NOTE: To utilize the Cloud LED, download the necessary tools and drivers from www.dell.com/support.
One unique feature of the Edge Gateway 3000 Series is the
the Edge Gateway by looking at the display light on the left panel of the Edge Gateway.
To enable this feature, you must expose and program a GPIO register on the Edge Gateway.
Follow these steps to control the Cloud LED on the Edge Gateway:
1.
Download the Cloud LED utility from www.dell.com/support.
2.
Extract the following files:
a.
DCSTL64.dll
b.
DCSTL64.sys
c.
DCSTL64.inf
d.
DCSTL64.cat
e.
CloudLED.exe
NOTE: These files must be in the same directory.
3.
Run the CloudLED.exe from Command Prompt or PowerShell with administrative rights. Run the following commands:
CloudLED.exe ON
CloudLED.exe OFF
48
Creating the recovery USB flash
<service tag> _ <date> _ <time> .txt
Accessing and updating the
Cloud LED . Cloud LED enables you to visually inspect the operational status of
drive.
BIOS.
Default BIOS
settings.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edge gateway 30013001N03g

Table of Contents