WIT-400HE Installation Manual THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND MAY NOT BE REPRODUCED OR COPIED WITHOUT EXPRESS WRITTEN PERMISSION OF A DULY AUTHORIZED REPRESENTATIVE OF LG-Ericsson Co.Ltd. Mar. 15-2012...
WIT-400HE Installation Manual Date: 15/M ar/2012 REVISION HISTORY ISSUE DATE REMARK 0.9A Mar. 15 2012 Wireless Part Preliminary Release 0.9A Mar. 20.2012 Jongmin Choi Update s/w upgrade process and system registration. This Document Contains proprietary information and may not be reproduced or copied without express...
WIT-400HE Installation Manual Date: 15/M ar/2012 TABLE OF CONTENTS SAFETY INSTRUCTIONS ..................6 SAFETY INFORMATION ..................6 GETTING STARTED ................... 7 1.1 O & B ..................... 7 PTIONS ASIC NCLOSURE 1.2 W ......................8 IRELESS ETWORK 1.3 A ..........................9...
Page 4
WIT-400HE Installation Manual Date: 15/M ar/2012 5.5 H ............................ 30 ANDOVER 5.6 T ..........................31 UNING OINTS IPECS LIK SETUP ..................33 6.1 MFIM S/W V ........................33 ERSION WIT-400HE R ..................... 33 EGISTRATION 6.2.1 MFIM S ........................33 ETTING 6.2.2 P...
Page 5
Date: 15/M ar/2012 REFACE The main objective of this document is to provide an instruction for proper installation of WIT-400HE. Mechanical feature is simply described and operation condition is precisely addressed to prevent the WIT-400HE from malfunctioning by environmental reason. In advance of the environmental consideration, please refer to this document it will help an installer in setting up basic circumstance for normal operation of the WIT-400HE.
WIT-400HE Installation Manual Date: 15/M ar/2012 Safety Instructions WARNING! To reduce the possibility of electric shock, do not expose your phone to high humidity areas, such as the bathroom, swimming pool, etc. Always store your phone away from heat. Never store your phone in settings that may expose it to temperatures less than 32°F or greater than 104°F, such as outside during a snow storm or in your car on...
Avoid shock or impact to the phone. Basic Enclosures: Unpacking the box, customer will see the following items. WIT-400HE WiFi Phone. You should be able to find MAC address tag at 1) WIT-400HE Phone the back side of the phone.
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 http://www.lge ericsson.com > 6) User r manual Download > M Manual-MPR Desktop hold er will be pro ovided. 7) Desk ktop Holder 8) Unit Label Options ser need to purchase de esktop holder r with additio onal payment...
The WIT-400HE is only 802.11b/g compliant, its maximum frequency is 2.4GHz and 54 Mbps maximum bandwidth. For more detail information of cell planning, please refer to the manual of AP. Access Point The following is a list of APs that have been made an imperative experimentation with the WIT-400HE and the result. Max retry...
WIT-400HE Installation Manual Date: 15/M ar/2012 Linksys AP. We found that sometime the AP doesn’t send packets after roaming in our laboratory investigation. O : We strongly recommend. ∆: It supports roaming feature, but it’s unstable or not verified enough.
1, then AP2 should have RF channel 6. If the RF channel number of the APs is overlapped near within 5 channels, the retransmission for data communication may be increased. As the result of this the standby time of WIT-400HE may be decreased and the voice quality will be very poor. So, you should check this carefully.
Basic IEEE 802.11b/g network diagram The following figure exhibits network infrastructure of 802.11b/g compliant network diagram. APs are connected to a HUB in subnet, since WIT-400HE is able to access the Internet. The iPECS LIK and WIT-400HE system work on top of this context.
(Delivery Traffic Indication MessageData Traffic Indication Map) & Beacon DTIM is related to an interval of packet transmission. By an inherent nature of the iPECS LIK, WIT-400HE frequently uses multicast message for the communication with the iPECS LIK. The delivery of multicast This Document Contains proprietary information and may not be reproduced or copied without express Written permission of a duly authorized representative of Ericsson-LG Co.Ltd.
WIT-400HE Installation Manual Date: 15/M ar/2012 message is affected by the DTIM parameter. Beacon is an indication of packets buffered in AP which are to be delivered to each wireless station, WIT- 400HE. The information of DTIM is contained in a beacon message. Therefore, DTIM configuration can be affected by the beacon interval.
(3) Open a page “Security > SSID Manager” . You can see a edit box “SSID”. (4) Enter your SSID. S/W Upgrade WIT-400HE can be upgraded via USB or WLAN. Network configuration for upgrade 1. Connect PC LAN port to the network.
Server Port # S/W image file Starting Upgrade 1. When WIT-400HE is boot up completely, connect USB cable or WLAN network. 2. Press “*1475963#” + “Send” button. 3. Select “3. S/W Upgrade” and set the server IP, port and file name.
Page 17
<Upgrade> S/W Upgrading via MFIM WIT-400HE could be updated on MFIM web admin same as IP Phone upgrade process. 1. Open File Upload menu in MFIM web admin. This Document Contains proprietary information and may not be reproduced or copied without express...
Page 18
Date: 15/M ar/2012 서식 있음: 글꼴: (영어) Arial 2. Upload WIT-400HE f/w to MFIM. The f/w image of WIT-400HE is like GS93PXXXX.rom. 서식 있음: 글꼴: (영어) Arial 3. Select extension number to upgrade and press upgrade button to start. This Document Contains proprietary information and may not be reproduced or copied without express...
Page 19
WIT-400HE Installation Manual Date: 15/M ar/2012 서식 있음: 글꼴: (영어) Arial 4. WIT-400HE will start downloading f/w and upgrading s/w. <Download> <Upgrade> This Document Contains proprietary information and may not be reproduced or copied without express Written permission of a duly authorized representative of Ericsson-LG Co.Ltd.
3) Try “ping” to the IP address of WIT-400HE. - If replies, go to next step. - If not, check the network configuration of PC and WIT-400HE. 4) Run “wit400trace.exe” - If TCP port 3490 is not available, you can change as “wit400trace.exe [TCP port #]”.
- It takes around 20 seconds to get the data. - If it fails, check the network configuration of PC and WIT-400HE. - If WLAN of WIT-400HE is not connected, you can use USB cable. Starting Diag. Server of WIT-400HE 4.2.1...
- If i t fails, check k the network k configuratio on of PC and d WIT-400HE - If W WLAN of WIT T-400HE is n not connecte ed, you can u use USB cab ble.
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 2) You c can get the d iag. data on the directory y which wit40 00h_diag.exe e is running. 4.2.4 Diag. Sam mple Data ======= ========== ========== ========== =========== ========== ========== Diag g information n for WIT-400...
Page 24
WIT-400HE Installation Manual Date: 15/M ar/2012 RX bytes:27521982 (26.2 MiB) TX bytes:9622734 (9.1 MiB) Interrupt:10 Base address:0xa000 << PING TEST RESULT TO SYSTEM >> PING 192.168.123.100 (192.168.123.100): 56 data bytes 64 bytes from 192.168.123.100: seq=0 ttl=127 time=23.590 ms 64 bytes from 192.168.123.100: seq=1 ttl=127 time=8.909 ms 64 bytes from 192.168.123.100: seq=2 ttl=127 time=5.482 ms...
WIT-400HE Installation Manual Date: 15/M ar/2012 Cell Planning Access Point Requirements To determine the number of Access Point in a system, you should consider Access Point broadcast range. Access Point Range In a typical office environment, each Access Point has a broadcast range of 50 meters and supports an area of 8,000 square meters, but a broadcast range depends entirely upon office environment.
Page 26
WIT-400HE Installation Manual Date: 15/M ar/2012 situations. The solution is to increase the radio coverage area. A. RF channel Specification The IEEE 802.11 b/g standard establishes several requirements for the RF transmission characteristics of an 802.11 radio. These channels have a center frequency separation of only 5 MHz and an overall channel bandwidth (or frequency occupation) of 22MHz.
Page 27
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 C. QoS S Service If you have a an AP which h could be ma ade editable e QoS service e, it could su upport good v voice quality during the te erminal’s han ndover to en nable QoS se...
Page 28
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 3. QoS Pol licies > Radio o-802.11g A ccess Catog gories You cou ld enable “B ackground(C CoS 1-2)”, “B Best Effort(Co os0,3)” and “ “Voice(Cos6- -7)”. 4. QoS Pol licies > Crea te/Edit, Appl y policies After you...
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 5. QoS : En nables RSSI Mon nitoring This fun nction helps that the de ealer can ins stall access point instru ument. The RSSI (Rece eived Signal Strength h Indicator) le evel of an ac ccess point o of which the...
WIT-400HE Installation Manual Date: 15/M ar/2012 RSSI Check (-75dBm) [Figure 3. Cell Boundary Map AP1 & AP 2] Handover Handover feature is supported in default profile which is the first profile in profile setting menu. Profile name and SSID of default profile is initialized “System Default” in Fig.4 . The default profile cannot be deleted and can be edited.
WIT-400H HE Installatio on Manual Date: 15 /M ar/2012 [Figure 5. Setting ro aming level] Hando over is exec cuted when signal level is 10dBm above the n noise level ( (normally sig gnal level is -75dBm ~ -80 dBm) Tuning Po oints 1.
Page 32
5 channels between adjacent APs. Can you talk across the roaming area? - Review the cell planning. The adjacent cell is (WIT-400HE guarantees roaming time overlapped enough? less than 500ms in well designed WLAN - Check the AP support seamless roaming. We don’t network.)
Date: 15/M ar/2012 iPECS LIK Setup MFIM S/W Version WIT-400HE is recognized as IPKTS phone type in MFIM in iPECS LIK can be registered without any license. Note) iPECS LIK 50/100/300 support WIT-400HE, and iPECS LIK 600/1200 need to install VOIM board additionally.
WIT-400HE Installation Manual Date: 15/M ar/2012 6.2.2 Profile Setting of WIT-400HE Press “AP Scanning” button on navigation up key in the idle status. Select SSID and press “Add” to add profile. Set Profile Name and Network Name (SSID) and press “Next”.
ECS System 6.2.4 Trouble S Shooting fo or Register ring Fault While W WIT-400HE tr ries to regist ter to system m, the follow wing error m message cou uld be displa ayed. If error message e’s displayed...
Page 36
IDs on Menu 442. Can't register to system System responded error message on registering request. Please check the iPECS System ’s Mac address and password. This Document Contains proprietary information and may not be reproduced or copied without express...
Manual Date: 15 /M ar/2012 iPECS CM Set CM Versio WIT-400 0HE is recog nized as IPK KTS phone ty ype in iPECS S CM. WIT-4 400HE can b be registered d without any license. WIT-400H HE Registra ation 7.2.1...
Page 38
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user's authority to operate the equipment.