Specifications

Table 1-1 Rosemount 400/400VP contacting conductivity sensor specifications
Wetted materials
Electrodes
Insulator
Body
O-ring
Temperature range
Standard
With Optional Integral Junction Box
Maximum pressure
250 psig (1825 kPa abs)
Vacuum
At 1.6 in. Hg air leakage is less than 0.005 SCFM (0.00014 m
Cell constants
0.01, 0.1, and 1.0/cm
Process connection
¾ in. MNPT
Cable
10 ft (3.1 m) standard; 50 ft (15.2m) optional; interconnecting VP6 cables sold separately (see Accessories)
Table 1-2 Flow cell (24092-02) specifications
Wetted materials
Body and Nut
¼ in. Fittings
O-ring
Process connection
Compression fitting for ¼ in. OD tubing
Temperature range
32 to 158 °F (0 to 70 °C)
Maximum pressure
90 psig (722 kPa abs)
Flow cell sold separately; see Accessories.
Specifications
Titanium
Glass Filled PEEK
316 Stainless Steel
EPDM
32 to 221 °F (0 to 105 °C)
32 to 392 °F (0 to 200 °C)
/min)
3
Polycarbonate and polyester
316 Stainless Steel
Silicone