The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control and the
rear panel RS-232 9-pin, D connector has the following pin assignments:
NOTE: If contact closure is not in use, pins 1, 4, 6, and 7 should have no connection.

Host to Scaler Communications

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the DVS 304 determines that a
command is valid, it executes the command and sends a response to the host device.
All responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ]), signalling the end of the response character string (one or more characters).

Scaler-initiated Messages

When a local event such as a front panel selection or adjustment takes place, the DVS 304
scaler responds by sending a message to the host. No response is required from the host.
Some scaler-initiated messages are listed here.
(C) Copyright 2010, Extron Electronics, DVS 304 series, Vx.xx ] The DVS 304 sends
the copyright message when it first powers on. Vx.xx is the firmware version number.
In X! All ]
Reconfig ] (where X! is the input number). The DVS 304 sends this response when an
input is switched or when a new signal is detected.
Host to Scaler Communications
Command and Responses
Pin
RS-232 Function
1
Input #1
2
Tx
3
Rx
4
Input #2
5
Gnd
6
Input #3
7
Input #4
8
-
9
-
DVS 304 Series • SIS Communication and Control
) of commands, or by using the Signal
Description
Contact closure
Transmit data
Receive data
Contact closure
Signal ground
Contact closure
Contact closure
No connection
Reserved