Adjustments For The Second Lan Adapter Ec-1010 - Furuno FEA-2107-BB Installation Manual

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107-BB:
Table of Contents

Advertisement

3.3 Adjustments for the LAN Adapter EC-1010
3.3.1
Setup for the LAN adapter EC-1010 program
The following tools are needed for programming LAN adapter:
• Ordinary serial RS-232C line cable to make connection from COM1 port to Connector J13
of LAN Adapter.
You need to set the jumpers of the LAN adapter to enable connector J13 and programming
mode.
To change J1 (CH 1) connector to J13 Connector for programming, set as below.
J17
J14
J15
To enable manual startup and programming, set as below.
J16
3.3.2
IP address agreement for LAN Adapter EC-1010
The table below shows IP addresses for each device.
Device
First ECDIS
Second ECDIS
First LAN adapter
Second LAN adapter
First LAN adapter
Second LAN adapter
CTS1-GND
TXP
RXP
INIT-GND
IP Address
10.0.0.180
10.0.0.181
10.0.0.190
10.0.0.191
10.0.0.192
10.0.0.193
3. ADJUSTMENTS
Function
MAIN
BACKUP
st
MAIN 1
LAN adapter
nd
MAIN 2
LAN adapter
st
BACKUP 1
LAN adapter
nd
BACKUP 2
LAN adapter
3-65