State
Operati
ng
Non-
operati
ng
Notes:
1.
The system's internal temperature controls the rotating speed of the fan module. Therefore,
this standard value might be exceeded if the maximum load continues under high-
temperature environment or if a failure occurs in the system.
2.
Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient
temperature, drive configuration, and operating status. Maximum volume can reach 79 dB
during maintenance procedure for a failed ENC or power supply.
3.
Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes
from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating
status.

VSP G200 environmental specifications (DC power supply)

Temperature
Humidity
Vibration
Hitachi Virtual Storage Platform G200 Hardware Reference Guide
Controller
60 dB (Environmental temperature
1
32°C or less)
55 dB (Environmental temperature 32°C or less)
Item
Operating
Non-operating
Transport/storage)
Operating
Transportation/storage
Operating (m/s2)
Non-operating (m/s2)
Transport (packed)
(m/s2)
Environmental specifications for VSP G200
FMD
60 dB (Environmental temperature 32°C or
1
2
3
less)
,
,
(When accessing the dense intermix drive tray,
do not work for long times at the rear of the
rack.)
1
2
3
4
,
,
,
55 dB
CBSSD/CBSLD/
DBSD/DBLD
41°F to 104°F
(5°C to 40°C)
23°F to 131°F
(-5 to 55°C) in 16
hours
-22°F to 140°F
(-30°C to 60°C)
5% to 85% (non-
condensing)
5% to 95% (non-
condensing)
2.5 or less (5 to 300
Within 5 seconds
Hz)
(Resonance point:10 Hz or less)
5.0 or less (5 to 300
Hz): No critical
damage for product.
9.8 (1.0 G) Adopt fall-
prevention safety
measures.
5.0 or less
Notes
89

Hide quick links:

Advertisement

Table of Contents
loading