Service processor description

The SVP provides four RJ-45 ports:
• Two ports connect to the storage system controllers (one port for each
• One port connects to the IP network of the user.
• One port connects to a user-supplied management console PC.
Note: This product is also designed for IT power distribution systems with
phase-to-phase voltage.
Three of the four RJ-45 ports (which connect to the controllers and the IP
network) are configured as a bridge. The SVP can be addressed using the
default IP address 192.168.0.15.
In the unlikely event you cannot connect to the SVP using the default IP
address, use the following emergency login: http://<default SVP IP
address>/dev/storage/<model number><system serial number>/
emergency.do. For example:
Storage system model number
8320004
8340004
8360004
Users are responsible for adopting the appropriate security procedures with
the SVP, including:
• Applying Windows security patches.
• Turning on automatic Windows updates or using the manual Windows
• Installing antivirus software that has been tested and approved by Hitachi.

SVP front panel

The front panel of the physical SVP is equipped with LEDs, a reset button,
and a power button.
62
controller).
update method.
VSP service processor server
Hitachi Virtual Storage Platform G200 Hardware Reference Guide
Storage system serial number
456789
456789
456789
URL
http://192.168.0.15/dev/
storage/8320004456789/
emergency.do
http://192.168.0.15/dev/
storage/8340004456789/
emergency.do
http://192.168.0.15/dev/
storage/8360004456789/
emergency.do

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents