Appendix C: Environmental specifications for
VSP G400, G600
The environmental specifications are described for the storage systems.

Environmental specifications

Temperature
Caution: The following storage system components are not supported in high-
temperature environments. Do not operate the following components at
temperatures of 40°C or higher:
DB60 dense drive tray
HDS provided service processor (SVP) server
First-generation FMDs (non-DC2 FMDs)
State
Operating
Non-operating
Transport,
storage
Temperature
change rate
(°C/h)
State
Operating

Appendix C: Environmental specifications for VSP G400, G600

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide
SFF, LFF drive
Controller
trays
50°F to 104°F
50°F to 104°F
(10°C to 40°C)
(10°C to 40°C)
14°F to 122°F
14°F to 122°F
(-10°C to 50°C)
(-10°C to 50°C)
-22°F to 140°F
-22°F to 140°F
(-30°C to 60°C)
(-30°C to 60°C)
10 or less
Controller
50°F to 104°F
DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is
(10°C to 40°C)
installed: 50°F to 95°F (10°C to 35°C)
Dense intermix drive tray
50°F to 95°F (10°C to 35°C)
14°F to 122°F (-10°C to 50°C)
-22°F to 140°F (-30°C to 60°C)
FMD drive trays