INTRODUCTION
This service manual describes the latest technical informa-
tion for the IC-F8101/F8100 ALE (Automatic Link Establish-
ment)/Selcall capabile HF TRANSCEIVER, at the time of
publication.
VERSION
MODEL
VERSION
NUMBER
EXP-04
AUS-04
IC-F8101
USA-04
IC-F8100
UN-04
RUS-04
EXP-05
IC-F8101
AUS-05
USA-05
IC-F8100
UN-05
CHN-05
RUS-05
EXP-06
IC-F8101
AUS-06
USA-06
IC-F8100
UN-06
ORDERING PARTS
Be sure to include the following four points when ordering
replacement parts:
1. 10-digit Icom part number
2. Component name
3. Equipment model name and unit name
4. Quantity required
<ORDER EXAMPLE>
1110003491 S.IC
TA31136FNG
8820001210 Screw 2438 screw
Addresses are provided on the inside back cover for your
convenience.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the
United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries.
TX
ACCESSORIE
POWER
#31
125W
#32
100W
#33
#34
125W
#36
HM-193
#41
#42
100W
#43
RMK-6
#44
125W
#45
#46
RMK-6, HM-193
#51
#52
100W
HM-192
#53
125W
#54
IC-F8101 MAIN-A UNIT 5 pieces
IC-F8101 Top cover
10 pieces
CAUTION
NEVER connect the transceiver to an AC outlet or to a DC
power supply that uses more than the specifi ed voltage. This
will ruin the transceiver.
DO NOT expose the transceiver to rain, snow or liquids.
DO NOT reverse the polarities of the power supply when con-
necting the transceiver.
DO NOT apply an RF signal of more than 20 dBm (100 mW) to
the antenna connector. This could damage the transceiver's
front-end.
To upgrade quality, any electrical or mechanical parts
and internal circuits are subject to change without notice
or obligation.
(IC-F8101 [#41])
REPAIR NOTES
1. Make sure that the problem is internal before dis-assem-
bling the transceiver.
2. DO NOT open the transceiver until the transceiver is dis-
connected from its power source.
3. DO NOT force any of the variable components. Turn them
slowly and smoothly.
4. DO NOT short any circuits or electronic parts. An insulated
tuning tool MUST be used for all adjustments.
5. DO NOT keep power ON for a long time when the trans-
ceiver is defective.
6. DO NOT transmit power into a Standard Signal Generator
or a Sweep Generator.
7. ALWAYS connect a 40/60 dB attenuator between the trans-
ceiver and a Deviation Meter or Spectrum Analyzer, when
using such test equipment.
8. READ the instructions of the test equipment thoroughly
before connecting it to the transceiver.