Mitsubishi Electric MELSERVO-J4 Instruction Manual Trouble Shooting page 65

Servo amplifier
Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

1. TROUBLESHOOTING
Alarm No.: E0
Name: Excessive regeneration warning
Alarm content
Detail
Detail name
No.
E0.1
Excessive
(1) The regenerative power
regeneration
warning
Alarm No.: E1
Name: Overload 1
Alarm content
Detail
Detail name
No.
E1.1
Thermal
(1) The load was over 85%
overload
warning 1
during
operation
E1.2
Thermal
(1) The load was over 85%
overload
warning 2
during
operation
E1.3
Thermal
(1) The load was over 85%
overload
warning 3
during
operation
E1.4
Thermal
(1) The load was over 85%
overload
warning 4
during
operation
E1.5
Thermal
(1) The load was over 85%
overload
warning 1
during a stop
E1.6
Thermal
(1) The load was over 85%
overload
warning 2
during a stop
E1.7
Thermal
(1) The load was over 85%
overload
warning 3
during a stop
E1.8
Thermal
(1) The load was over 85%
overload
warning 4
during a stop
There is a possibility that regenerative power may exceed permissible regenerative power of built-in
regenerative resistor or regenerative option.
Cause
Check the effective
exceeded 85% of the
load ratio.
permissible
regenerative power of
the built-in regenerative
resistor or regenerative
option.
[AL.50 Overload 1] or [AL.51 Overload 2] may occur.
Cause
Check it with the check method for [AL. 50.1].
to the alarm level of [AL.
50.1 Thermal overload
error 1 during
operation].
Check it with the check method for [AL. 50.2].
to the alarm level of [AL.
50.2 Thermal overload
error 2 during
operation].
Check it with the check method for [AL. 51.1].
to the alarm level of [AL.
51.1 Thermal overload
error 3 during
operation].
Check it with the check method for [AL. 50.3].
to the alarm level of [AL.
50.3 Thermal overload
error 4 during
operation].
Check it with the check method for [AL. 50.4].
to the alarm level of [AL.
50.4 Thermal overload
error 1 during a stop].
Check it with the check method for [AL. 50.5].
to the alarm level of [AL.
50.5 Thermal overload
error 2 during a stop].
Check it with the check method for [AL. 51.2].
to the alarm level of [AL.
51.2 Thermal overload
error 3 during
operation].
Check it with the check method for [AL. 50.6].
to the alarm level of [AL.
50.6 Thermal overload
error 4 during a stop].
Check method
Check result
It is 85% or more.
Check method
Check result
1 - 58
Action
Target
Reduce the frequency
[A]
of positioning.
[B]
[WB]
Increase the
[RJ010]
deceleration time
constant.
Reduce the load.
Use a regenerative
option if not being
using.
Action
Target
[A]
[B]
[WB]
[RJ010]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j4

Table of Contents