9 Technical data

Type 6111
Explosion protection
Input
Standard
Load
Explosion-protected version
without switch-off electronics
with Type 6112 i/p Module
Module A
Module B
Module C
Out-
Module D
put
Module E
Module F
Module G
Module H
Max. air output capacity
Supply air
Air quality acc. to ISO 8573-1:
2001
Power consumption
Characteristic
Hysteresis
Deviation from terminal-based
conformity
Effect in % of the upper range
value
Dynamic response
Limiting frequency
Phase shift
Variable position
Initial value raised up to 3.0 bar (special version)
1)
The max. possible output pressure is 8 bar.
2)
Measured with 2 m hose with 4 mm inside diameter.
3)
EB 6111 EN
Rail-mounting unit
II 2 G Ex ia IIC T6
4 to 20 mA (0 to 20 mA on request), for split-range: 4 to 12 mA or 12 to
Special ranges adjustable at the factory to meet customer specifications
Initial value
0.1 to 0.4 bar
0.1 to 0.4 bar
0.1 to 0.4 bar
0.1 to 0.8 bar
0.1 to 0.8 bar 
0.1 to 0.8 bar
0.1 to 1.2 bar
0.1 to 1.2 bar
2.0 m³/h at an output of 0.6 bar (0.2 to 1.0 bar)
2.5 m³/h at an output of 1.2 bar (0.4 to 2.0 bar)
3)
8.5 m³/h at an output of 5.0 bar (0.1 to 8.0 bar)
At least 0.4 bar above the upper signal pressure range value, max. 10 bar
Max. particle size and density: Class 4 · Oil content: Class 3 · Pressure dew
point: Class 3 or at least 10 K below the lowest ambient temperature to be
0.08 m
³/h at 1.4 bar · 0.1 m
n
≤1 % of upper range value (for upper range values up to 5 bar); more
≤1.5 % of upper range value (for upper range values above 5 bar)
Alternating load, supply air failure, interruption of the input current: <0.3 %
Ambient temperature: lower range value <0.03 %/K, span <0.03 %/K
Max. 3.5 % depending on mounting position: e.g. ± 1 % when mounted
20 mA, other signals on request
≤ 6 V (corresponding to 300 Ω at 20 mA)
7 V (corresponding to 350 Ω at 20 mA)
≤ 4 V (corresponding to 200 Ω at 20 mA)
0.2 to 1 bar (3 to 15 psi) (standard range)
0.4 to 2 bar (6 to 30 psi) (standard range)
2)
without supply pressure regulator
expected
³/h at 2.4 bar · Max. 0.26 m
n
Characteristic: Output linear to input
≤0.3 % of final value
exact values on request
Supply air: <0.1 %/0.1 bar
At an output of of 0.2 to 1 bar
5.3 Hz
–130°
horizontally
Technical data
Field unit
II 3 G Ex nA IIC T6
Span ∆p
0.75 to 1.0 bar
1.0 to 1.35 bar
1.35 to 1.81 bar
1.81 to 2.44 bar
2.44 to 3.28 bar
3.28 to 4.42 bar
4.42 to 5.94 bar
5.94 to 8.0 bar
1)
³/h at 10 bar
n
17