Page 1
EB 6134 EN Translation of original instructions Type 6134-04 p/i Converter with one or two p/i Type 6134-x3 p/i Converter, field unit converter units, rail-mounting unit Type 6134 p/i Converter for two-wire connection Edition May 2021...
Page 2
Note on these mounting and operating instructions These mounting and operating instructions assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices. The images shown in these instructions are for illustration purposes only. The actual product may vary.
SAMSON. SAMSON does not assume any liability for damage resulting from the failure to use the de- vice for its intended purpose or for damage caused by external forces or any other external factors.
Page 6
Î Check with the plant operator for details on further protective equipment. Revisions and other modifications Revisions, conversions or other modifications of the product are not authorized by SAMSON. They are performed at the user's own risk and may lead to safety hazards, for example. Fur- thermore, the product may no longer meet the requirements for its intended use.
Page 7
Devices with a CE marking fulfill the requirements of the Directives (see the 'Certificates' sec- tion): − Type 6134-0: 2014/30/EU, 2011/65/EU − Type 6134-1: 2014/30/EU, 2014/34/EU, 2011/65/EU − Type 6134-2: 2014/30/EU, 2014/34/EU, 2011/65/EU Devices with an EAC marking fulfill the requirements of the Regulations (see the 'Certificates' section): −...
There is a risk of personal injury. Î Keep all relevant markings and inscriptions on the device in a constantly legible state. Î Contact our after-sales service to renew damaged, missing or incorrect nameplates or labels. EB 6134 EN...
Î Refer to the technical data for the maximum permissible supply pressure. Î Make sure that the air supply does not exceed the maximum permissible supply pressure. EB 6134 EN...
Devices that have already been used outside hazardous areas and are intended for future use inside hazardous areas must comply with the safety requirements placed on serviced devices. They must be subjected to testing according to the specifications in EN 60079-19. EN 60079-19 applies to servicing explosion-protected devices. EB 6134 EN...
5 Output signal inductance) 6 Supply voltage of the two-wire circuit Fig. 2-1: Nameplate examples for Type 6134 p/i Converter Location of the nameplate − Rail-mounting unit: the nameplate is located at the front of the device. − Field unit: the nameplate is affixed with grooved pins to the side of the p/i converter.
Rail-mounting unit, screw terminals Field unit, ½-14 NPT Field unit, M20x1.5 Pneumatic connection Hose connection ¼-18 NPT ISO-228/1 - G ¼ Degree of protection IP 20 IP 54 IP 65 Pressure gauge Without With Temperature range ≥ –20 °C ≥ –40 °C Output signal 4 to 20 mA EB 6134 EN...
Capacitive pressure sensor Constant voltage source Measuring amplifier and 4...20 mA potentiometers for adjusting the measuring span (SPAN) and ZERO 0,2...1 bar (3...15 psi) 12...30V DC Fig. 3-2: Schematic diagram of the Type 6134 p/i Converter for two-wire connection EB 6134 EN...
Design and principle of operation 3.1 Technical data Type Type 6134-04 Types 6134-03, -13, -23 Version Rail-mounting unit Field unit Explosion protection according to ATEX – II 2G EEx ia IIC T6 II 2G EEx d IIC T6 p/i converter unit/device 1 or 2 Input 0.2 to 1 bar (3 to 15 psi), overloadable up to 5 bar...
Page 15
Bracket for wall mounting DIN EN 60715 (included in scope of delivery) or pipe mounting for 2” pipes (order no. 1400-5656) Type 6134-13: intrinsically safe circuit See 'Certificates' section for details (electric data, connection conditions, etc.) All errors specified based on output span EB 6134 EN...
SAMSON and the forwarding agent Î Observe the storage instructions. (refer to delivery note). Î Avoid long storage times. Î Contact SAMSON in case of different 4.2 Removing the packaging storage conditions. from the device Observe the following sequence: Note Î...
Page 18
In damp spaces, prevent condensa- tion. If necessary, use a drying agent or heating. − Observe storage temperature (see the 'Design and principle of operation' sec- tion). − Do not place any objects on the device. EB 6134 EN...
Proceed as follows: The work position is the front view onto the Î Lay out the necessary material and tools operating controls on the device seen from to have them ready during installation the position of operating personnel. work. EB 6134 EN...
Î Fasten the mounting bracket to the back vention regulations of the employers’ liability of the converter using two screws. insurance. Î Place the clamp around the pipe. Hold it in position and fasten it to the mounting bracket. EB 6134 EN...
Page 21
* For explosion-protected versions (Ex ia) converter unit. intrinsically safe circuit (see type examination certificate in the 'Certificates' section) Output – – 31 32 – – – – 24V DC – – 24V DC * – Fig. 5-2: Electrical connection EB 6134 EN...
Rail-mounting unit The connection is designed as a hose con- nection for 4x1 mm hose. Î Connect the air line from the upstream pneumatic device issuing the positioning value to the hose connection (see Fig. 5-3). EB 6134 EN...
Page 23
Installation Rail-mounting unit Field unit * Only input 1 is assigned in the version with one p/i converter unit. Input Input 1* Input 2 Fig. 5-3: Supply air line (input signal) EB 6134 EN...
Order no. 1400-8837 (included − Bracket for wall mounting, stainless steel (1.4301) in scope of delivery) − Wall and pipe mounting (2" pipes) 1400-5656 Pressure gauge retrofit for field unit − Pressure gauge including lock nut 1400-8838 EB 6134 EN...
(see the 'Installation' section). Note The converter is tested by SAMSON and the output signal is adjusted to the required range. In case of inconsistencies caused by the converter despite it being mounted cor- rectly, the zero and span can be retuned (see the 'Servicing' section).
Î Put the device out of operation when its exceed the maximum supply pressure. cover thread or connecting thread is damaged. Replace it with a new device. 7.1 Troubleshooting Î See Table 7-1 Note Contact SAMSON's After-sales Service for malfunctions not listed in the table. EB 6134 EN...
Î Check electrical connection p/i converter does not reach Incorrect electrical connection (see the 'Installation' 100 % output e.g. 1 bar input: section). output only 70 % instead of 100 % Î Check the pneumatic con- Incorrect pneumatic connection nection (see the 'Installation' section). EB 6134 EN...
The output signal of the measuring instrument must now indicate 4 mA. Note Î Correct deviations at the ZERO po- The device was checked by SAMSON before tentiometer. it left the factory. Î Tune span: − The product warranty becomes void if Î...
Table 8-1 at the minimum. Rail-mounting unit Field unit For versions ZERO with only one p/i converter unit SPAN (Type 6134- 041), only the SPAN and ZERO SPAN potentiometers on '1' are ZERO active SPAN ZERO Fig. 8-1: Tuning zero and span EB 6134 EN...
Page 31
Action to be taken in the event of a negative re- sult Check the markings, labels and nameplates on Contact SAMSON when nameplates or labels are the converter for their readability and complete- damaged, missing or incorrect to renew them.
(see the 'Decommissioning' section). Î Remove air lines. Î Disconnect the electrical wires. Î Rail-mounting unit: Remove the converter from the top-hat rail. Field unit: Unscrew the four screws for wall mount- ing on the bracket. EB 6134 EN...
EN 60079-19 applies to servicing explo- Î Do not perform any repair work on your sion-protected devices. own. Î Contact SAMSON's After-sales Service 10.2 Returning devices to for repair work. SAMSON Defective devices can be returned to 10.1 Servicing explosion-...
Disposal 11 Disposal SAMSON is a producer registered at the following European institution u https:// www.ewrn.org/national- registers/national-registers. WEEE reg. no.: DE 62194439/FR 025665 Î Observe local, national and internation- al refuse regulations. Î Do not dispose of components, lubricants and hazardous substances together with your other household waste.
Page 39
Certificates 12 Certificates The following certificates are included on the next pages: − Type 6134-0: EU declaration of conformity − Type 6134-1: EU declaration of conformity − Type 6134-2: EU declaration of conformity − TR CU certificate − Type 6134-1: EC type examination certificate (ATEX) −...
Page 40
Leiter Qualitätssicherung/Head of Quality Managment/ Zentralabteilungsleiter/Head of Department/Chef du département Responsable de l'assurance de la qualité Entwicklungsorganisation/Development Organization SAMSON AKTIENGESELLSCHAFT Telefon: 069 4009-0 · Telefax: 069 4009-1507 Revison 07 Weismüllerstraße 3 60314 Frankfurt am Main E-Mail: samson@samson.de 12-2 EB 6134 EN...
Page 41
Leiter Qualitätssicherung/Head of Quality Managment/ Zentralabteilungsleiter/Head of Department/Chef du département Responsable de l'assurance de la qualité Entwicklungsorganisation/Development Organization SAMSON AKTIENGESELLSCHAFT Telefon: 069 4009-0 · Telefax: 069 4009-1507 Revison 07 Weismüllerstraße 3 60314 Frankfurt am Main E-Mail: samson@samson.de EB 6134 EN 12-3...
Page 42
Leiter Qualitätssicherung/Head of Quality Managment/ Zentralabteilungsleiter/Head of Department/Chef du département Responsable de l'assurance de la qualité Entwicklungsorganisation/Development Organization SAMSON AKTIENGESELLSCHAFT Telefon: 069 4009-0 · Telefax: 069 4009-1507 Revison 07 Weismüllerstraße 3 60314 Frankfurt am Main E-Mail: samson@samson.de 12-4 EB 6134 EN...
Page 53
You can reach our after-sales service at aftersalesservice@samsongroup.com. Addresses of SAMSON AG and its subsid- iaries The addresses of SAMSON AG, its subsid- iaries, representatives and service facilities worldwide can be found on our website (www.samsongroup.com) or in all SAMSON product catalogs.