CT Express™ Checklist
Use this list as a final check of appliance installation conformance
Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims
Clearances:
Left: 4" (102mm) — 18" (457mm) recommended service access
8" (203mm) from heat or steam producing equipment
Right: 4" (102mm) non‑combustible surfaces
Rear: 4" (102mm) for plumbing
Top: 20" (508mm) for air movement
Water Supply And Drains:
Verify hook up of two (2) cold water lines: treated and untreated
water with a 3/4" (19mm) G inside diameter connection supply line
Verify inlet water pressure is at a minimum of 30 PSI (200 kPa)
dynamic Maximum water pressure is not to exceed 90 PSI (600 kPa)
static Verify drain diameter of 1‑1/2" (40mm) with a positive
descending slope, and with a 2" (51mm) air gap which is free of
obstructions before connection to the site drain Verify 1/8" (3 2mm)
pitch to 10' (305cm) of drain line Materials must withstand
temperatures up to 200°F (93°C)
NOTICE: Alto‑Shaam has listed Water Quality Requirements in the installation manual for this equipment It is the
responsibility of the end user to have the water connected to this appliance tested to ensure these standards
are met before putting the appliance into use Failure to meet these standards will void the warranty if
damage to the appliance is found to be related to water quality
Inspect water connections inside the combi
Check all lines and connections for leaks, both inside and outside the combi

Electrical Connections:

Verify electrical power requirements for appliance
Verify voltage at terminal block
Check all terminals for tightness
Voltage:
Phase:
Breaker size:
Control Board Connections & Operation:
ExpressTouch: With the power on, press the Tool Box
icon, then the Settings icon to access software version
in the upper left corner
Record software version: DB__________________
Physical Condition:
Bottom of appliance has been checked for damage due to improper positioning on site
Verify all gaskets and hoses are in place and function properly
Verify the installation of drip pans*, racks, shelves, drain screen, spray hose*
Verify the appliance is level and installed on a solid, water resistant surface
Service Agency:
Model No :
Tech Signature:
MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
______________
______________
______________
RB__________________
*Reference installation instructions for complete information
Are all clearance
requirements met?
If no, explain: ____________________________
____________________________________________
Bottom: 4" (102mm) for air movement
Are both water supply lines
properly connected?
If no, explain: ________________________________
Is a filter system installed
on this appliance?
Store has seen this
recommendation:
Signature of store representative:
________________________________________________
Line voltage at terminal block (to ground):
Line 1: __________ Line 2: __________ Line 3: __________
Line voltage (phase to phase):
Electrical supply line size: _____________________________
All electrical terminals tight:
All board connections tight:
All functions are displayed:
All functions on control operate:
Appliance operates in all modes:
If no, explain: _______________________________________________
_______________________________________________________________
Start‑Up Date:
Installation Name:
Serial No :
Customer Signature:
Installation
Yes
No
Yes
No
Yes
No
Yes
No
Line 1 to 2: __________
Line 2 to 3: __________
Line 3 to 1: __________
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No