Wiring; Typical Wiring - GE UR Series F60 Instruction Manual

Feeder protection system
Hide thumbs Also See for UR Series F60:
Table of Contents

Advertisement

3 HARDWARE

3.2WIRING

This diagram is based on the following order code:
F60-E00-HCH-F8F-H6B-M6K-P6C-U6D-W6A
This diagram provides an example of how the device
is wired, not specifically how to wire the device. Please
refer to the Instruction Manual for additional details on
wiring based on various configurations.
Ground at
GE Multilin
TYPICAL CONFIGURATION
POSITIVE WATTS
A B C
OPEN DELTA
VT CONNECTION (ABC)
VOLTAGE INPUTS
H7a
H7c
H8a
H8c
H7b
H8b
W5a
W5c
W6a
W6c
W5b
W7a
W7c
W8a
W8c
W7b
W8b
U1a
U1c
U2a
U2c
U1b
U3a
U3c
U4a
U4c
U3b
U5a
U5c
U6a
U6c
U5b
U7a
U7c
U8a
U8c
U7b
U8b
B1b
B1a
B2b
DC
B3a
B3b
B5b
HI
B6b
LO
AC or DC
B6a
B8a
Shielded
B8b
twisted pairs
D1b
D2b
D3b
COM
Remote
D1a
Device
D2a
D3a
COM
D4b
Co-axial *
D4a
Co-axial
BNC
Co-axial
BNC
Co-axial * - For IRIG-B Input
only use one
No. 10AWG
Minimum
terminal as input
GROUND BUS
X
MODULES MUST BE
GROUNDED IF
Inputs/
TERMINAL IS
outputs
PROVIDED
* Optional
Figure 3–11: TYPICAL WIRING DIAGRAM
F60 Feeder Protection System
THE AC SIGNAL PATH IS CONFIGURABLE
(5 Amp CT)
52
VOLTAGE INPUTS
CURRENT INPUTS
8F / 8G
CONTACT INPUT H7a
DIGITAL INPUTS/OUTPUTS
6B
H1
CONTACT INPUT H7c
V
CONTACT INPUT H8a
CONTACT INPUT H8c
H2
COMMON H7b
V
SURGE
H3
GE Consumer & Industrial
H4
Multilin
H5
F60
FEEDER MANAGEMENT RELAY
H6
CONTACT INPUT W5a
DIGITAL INPUTS/OUTPUTS
6A
CONTACT INPUT W5c
W1
V
CONTACT INPUT W6a
CONTACT INPUT W6c
COMMON W5b
W2
V
CONTACT INPUT W7a
CONTACT INPUT W7c
W3
CONTACT INPUT W8a
CONTACT INPUT W8c
COMMON W7b
W4
SURGE
P1
CONTACT INPUT U1a
CONTACT INPUT U1c
CONTACT INPUT U2a
P2
CONTACT INPUT U2c
COMMON U1b
CONTACT INPUT U3a
P3
CONTACT INPUT U3c
CONTACT INPUT U4a
CONTACT INPUT U4c
P4
COMMON U3b
CONTACT INPUT U5a
P5
CONTACT INPUT U5c
CONTACT INPUT U6a
CONTACT INPUT U6c
P6
COMMON U5b
CONTACT INPUT U7a
CONTACT INPUT U7c
P7
CONTACT INPUT U8a
CONTACT INPUT U8c
COMMON U7b
P8
SURGE
RS-232
DB-9
CRITICAL
(front)
M1
FAILURE
48 VDC
CONTACTS SHOWN
OUTPUT
WITH NO
M2
CONTROL POWER
CONTROL
POWER
M3
SURGE
FILTER
M4
RS485
COM 1
M5
RS485
COM 2
M6
IRIG-B
Input
M7
IRIG-B
Output
M8
832769A4.CDR
MODULE ARRANGEMENT
W
V
U
T
S
R
P
N
M
L
K
J
H
G
F
D
6
6
6
6
6
8
9
Inputs/
Inputs/
Inputs/
outputs
outputs
outputs
Inputs/
CT/VT
CPU
*
*
*
*
outputs
(Rear view)
3.2 WIRING

3.2.1 TYPICAL WIRING

CONNECTION
AS REQUIRED
H1a
TC
1
I
H1b
H1c
H2a
I
H2b
H2c
H3a
H3b
TC
2
H3c
H4a
H4b
H4c
H5a
H5b
H5c
H6a
H6b
H6c
W1a
I
W1b
W1c
W2a
I
W2b
W2c
W3a
W3b
W3c
W4a
W4b
W4c
P1a
P1b
P1c
P2a
P2b
P2c
P3a
P3b
P3c
UR
COMPUTER
P4a
1 8
1
P4b
2
2
3
TXD
RXD
P4c
RXD
3
3
2
TXD
P5a
4
4
20
P5b
SGND
5
5
7
SGND
P5c
6
6
6
P6a
7
7
4
P6b
8
8
5
P6c
9
9
22
P7a
P7b
25 PIN
9 PIN
P7c
CONNECTOR
CONNECTOR
P8a
P8b
P8c
M1a
M1b
M1c
M2a
M2b
M2c
M3a
M3b
M3c
M4a
M4b
M4c
M5a
M5b
M5c
M6a
M6b
M6c
M7a
M7b
M7c
M8a
M8b
M8c
B
1
Power
Supply
3
3-9

Advertisement

Table of Contents
loading

Table of Contents