B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 46 of 51)
ADDR
REGISTER NAME
C71C
...Repeated for Contact Output 62
C728
...Repeated for Contact Output 63
C734
...Repeated for Contact Output 64
Reset (Read/Write Setting)
C750
FlexLogic™ operand which initiates a reset
B
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Clear Records (Read/Write Setting)
C770
Clear Fault Reports operand
C772
Clear Event Records operand
C773
Clear Oscillography operand
C774
Clear Data Logger operand
C775
Clear Breaker 1 Arcing Current operand
C776
Clear Breaker 2 Arcing Current operand
C77B
Clear Demand operand
C77D
Clear Energy operand
C77E
Clear Hi-Z Records operand
C77F
Clear Unauthorized Access operand
C781
Clear Platform Direct Input/Output Statistics operand
C782
Reserved (13 items)
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input x State (96 items)
C800
Force Contact Output x State (64 items)
Direct Inputs/Outputs (Read/Write Setting)
C880
Direct Device ID
C881
Direct I/O Channel 1 Ring Configuration Function
C882
Platform Direct I/O Data Rate
C883
Direct I/O Channel 2 Ring Configuration Function
C884
Platform Direct I/O Crossover Function
Direct input/output commands (Read/Write Command)
C888
Direct input/output clear counters command
Direct inputs (Read/Write Setting) (96 modules)
C890
Direct Input 1 Device Number
C891
Direct Input 1 Number
C892
Direct Input 1 Default State
C893
Direct Input 1 Events
C894
...Repeated for Direct Input 2
C898
...Repeated for Direct Input 3
C89C
...Repeated for Direct Input 4
C8A0
...Repeated for Direct Input 5
C8A4
...Repeated for Direct Input 6
C8A8
...Repeated for Direct Input 7
C8AC
...Repeated for Direct Input 8
C8B0
...Repeated for Direct Input 9
C8B4
...Repeated for Direct Input 10
C8B8
...Repeated for Direct Input 11
C8BC
...Repeated for Direct Input 12
B-54
RANGE
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 2
0 to 3
1 to 16
0 to 1
64 to 128
0 to 1
0 to 1
0 to 1
0 to 16
0 to 96
0 to 3
0 to 1
F60 Feeder Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F144
---
1
F131
---
1
F001
---
1
F126
kbps
64
F001
---
1
F126
---
1
F102
---
1
F126
---
1
F001
---
1
F001
---
1
F086
---
1
F102
DEFAULT
0
0 (Disabled)
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (Disabled)
1
0 (No)
64
0 (No)
0 (Disabled)
0 (No)
0
0
0 (Off)
0 (Disabled)
GE Multilin