GE UR Series F60 Instruction Manual page 370

Feeder protection system
Hide thumbs Also See for UR Series F60:
Table of Contents

Advertisement

A.1 PARAMETER LIST
Table A–1: FLEXANALOG DATA ITEMS (Sheet 4 of 13)
A
ADDRESS
FLEXANALOG NAME
7553
SRC 2 Frequency
7680
SRC 1 Demand Ia
7682
SRC 1 Demand Ib
7684
SRC 1 Demand Ic
7686
SRC 1 Demand Watt
7688
SRC 1 Demand var
7690
SRC 1 Demand Va
7696
SRC 2 Demand Ia
7698
SRC 2 Demand Ib
7700
SRC 2 Demand Ic
7702
SRC 2 Demand Watt
7704
SRC 2 Demand var
7706
SRC 2 Demand Va
8064
SRC 1 Va THD
8065
SRC 1 Va Harm[0]
8066
SRC 1 Va Harm[1]
8067
SRC 1 Va Harm[2]
8068
SRC 1 Va Harm[3]
8069
SRC 1 Va Harm[4]
8070
SRC 1 Va Harm[5]
8071
SRC 1 Va Harm[6]
8072
SRC 1 Va Harm[7]
8073
SRC 1 Va Harm[8]
8074
SRC 1 Va Harm[9]
8075
SRC 1 Va Harm[10]
8076
SRC 1 Va Harm[11]
8077
SRC 1 Va Harm[12]
8078
SRC 1 Va Harm[13]
8079
SRC 1 Va Harm[14]
8080
SRC 1 Va Harm[15]
8081
SRC 1 Va Harm[16]
8082
SRC 1 Va Harm[17]
8083
SRC 1 Va Harm[18]
8084
SRC 1 Va Harm[19]
8085
SRC 1 Va Harm[20]
8086
SRC 1 Va Harm[21]
8087
SRC 1 Va Harm[22]
8088
SRC 1 Va Harm[23]
8089
SRC 1 Vb THD
8090
SRC 1 Vb Harm[0]
8091
SRC 1 Vb Harm[1]
8092
SRC 1 Vb Harm[2]
8093
SRC 1 Vb Harm[3]
8094
SRC 1 Vb Harm[4]
8095
SRC 1 Vb Harm[5]
8096
SRC 1 Vb Harm[6]
8097
SRC 1 Vb Harm[7]
A-4
UNITS
DESCRIPTION
Hz
Source 2 frequency
Amps
Source 1 phase A current demand
Amps
Source 1 phase B current demand
Amps
Source 1 phase C current demand
Watts
Source 1 real power demand
Vars
Source 1 reactive power demand
VA
Source 1 apparent power demand
Amps
Source 2 phase A current demand
Amps
Source 2 phase B current demand
Amps
Source 2 phase C current demand
Watts
Source 2 real power demand
Vars
Source 2 reactive power demand
VA
Source 2 apparent power demand
---
Source 1 phase A voltage total harmonic distortion (THD)
Volts
Source 1 phase A voltage second harmonic
Volts
Source 1 phase A voltage third harmonic
Volts
Source 1 phase A voltage fourth harmonic
Volts
Source 1 phase A voltage fifth harmonic
Volts
Source 1 phase A voltage sixth harmonic
Volts
Source 1 phase A voltage seventh harmonic
Volts
Source 1 phase A voltage eighth harmonic
Volts
Source 1 phase A voltage ninth harmonic
Volts
Source 1 phase A voltage tenth harmonic
Volts
Source 1 phase A voltage eleventh harmonic
Volts
Source 1 phase A voltage twelfth harmonic
Volts
Source 1 phase A voltage thirteenth harmonic
Volts
Source 1 phase A voltage fourteenth harmonic
Volts
Source 1 phase A voltage fifteenth harmonic
Volts
Source 1 phase A voltage sixteenth harmonic
Volts
Source 1 phase A voltage seventeenth harmonic
Volts
Source 1 phase A voltage eighteenth harmonic
Volts
Source 1 phase A voltage nineteenth harmonic
Volts
Source 1 phase A voltage twentieth harmonic
Volts
Source 1 phase A voltage twenty-first harmonic
Volts
Source 1 phase A voltage twenty-second harmonic
Volts
Source 1 phase A voltage twenty-third harmonic
Volts
Source 1 phase A voltage twenty-fourth harmonic
Volts
Source 1 phase A voltage twenty-fifth harmonic
---
Source 1 phase B voltage total harmonic distortion (THD)
Volts
Source 1 phase B voltage second harmonic
Volts
Source 1 phase B voltage third harmonic
Volts
Source 1 phase B voltage fourth harmonic
Volts
Source 1 phase B voltage fifth harmonic
Volts
Source 1 phase B voltage sixth harmonic
Volts
Source 1 phase B voltage seventh harmonic
Volts
Source 1 phase B voltage eighth harmonic
Volts
Source 1 phase B voltage ninth harmonic
F60 Feeder Protection System
APPENDIX A
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents