System Fans - HP ProLiant ML350 Maintenance And Service Manual

Generation 5 server
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

Remove the air baffle.
4.
To replace the component, reverse the removal procedure.

System fans

CAUTION: The system fan is a non-hot-pluggable device.
Fan failures are indicated by amber LEDs located on each hot-plug fan and by the front panel internal
health LED. When a fan failure occurs, the internal health LED illuminates red in non-redundant mode and
amber in redundant mode.
To remove the component:
Power down the server (on page 26).
1.
Do one of the following:
2.
Unlock and remove the bezel
Extend the server from the rack (on page 26).
Remove the access panel
3.
Remove the air baffle
4.
Disconnect the system fan cable from the system board
5.
("Front
bezel" on page 27).
("Access
panel" on page 29).
("Air
baffle" on page 33).
("System board
components" on page 64).
Removal and replacement procedures 34

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents