Fig. 54: Setting the potentiometer
6. Check whether the lifting gear plates are flush.
10.Loosen the setscrew (3).
11.Turn the potentiometer axle such that the left display shows 1 in the first
12.Tighten the setscrew (3) without changing the value shown in the dis-
13.Press the ESC key two times.
Important:
14.Switch off the machine at the main switch.
15.Switch on the machine at the main switch.
 Switching off and on will save the setting.
64
(1) - Setscrews
(2) - Connecting clamp for lifting cylinder
If the plates are not flush:
7.Loosen the setscrews (1).
8.Set the connecting clamp (2) for the lifting cylinder such that the plates
are flush.
9.Tighten the setscrews (1).
instance and the relevant maximum speed next to it.
play.
Setting the potentiometer
(3) - Setscrew for the setting shaft
(4) - Potentiometer
Service manual 567 classic - 01.0 - 10/2015