Correct setting
The needle thread slides through unobstructed between the nose of the
spool housing and the recess in the throat plate.
Cover
• Tilt the upper section ( 3.3.1 Access to the machine bottom section,
• Throat plate slide ( 3.3.5 Opening and closing the throat plate slide,
Fig. 33: Setting the lifting gap
Setting steps
1. Loosen the screw (3).
2. Push the cover (2) downwards.
3. Loosen the setscrew (1).
4. Set the spool housing lifter such that the gap between the nose of the
5. Tighten the setscrew (1).
6. Push the cover (2) upwards.
7. Tighten the screw (3).
44
page 10)
page 13)
(1) - Setscrew
(2) - Cover
spool housing and the recess in the throat plate is just big enough to
allow the needle thread to slip through without a problem.
While doing so, ensure that the gap is not so big that the middle part of
the hook swings to and fro, hitting the recess in the throat plate.
Setting the bobbin housing lifter
(3) -
Screw
(4) -
Bobbin housing lifter