Security; Availability; Usage; Force-Enter Bios Setup - Intel S1400SP Technical Manual

Hide thumbs Also See for S1400SP:
Table of Contents

Advertisement

Advanced Management Feature Support (RMM4)
For the best possible KVM performance, a 2Mb/sec link or higher is recommended.
The redirection of KVM over IP is performed in parallel with the local KVM without affecting the
local KVM operation.
7.1.3

Security

The KVM redirection feature supports multiple encryption algorithms, including RC4 and AES.
The actual algorithm that is used is negotiated with the client based on the client's capabilities.
7.1.4

Availability

The remote KVM session is available even when the server is powered-off (in stand-by mode).
No re-start of the remote KVM session shall be required during a server reset or power on/off.
An BMC reset (for example, due to an BMC Watchdog initiated reset or BMC reset after BMC
FW update) will require the session to be re-established.
KVM sessions persist across system reset, but not across an AC power loss.
7.1.5

Usage

As the server is powered up, the remote KVM session displays the complete BIOS boot
process. The user is able interact with BIOS setup, change and save settings as well as enter
and interact with option ROM configuration screens.
At least two concurrent remote KVM sessions are supported. It is possible for at least two
different users to connect to same server and start remote KVM sessions.
7.1.6

Force-enter BIOS Setup

KVM redirection can present an option to force-enter BIOS Setup. This enables the system to
enter F2 setup while booting which is often missed by the time the remote console redirects the
video.
7.2

Media Redirection

The embedded web server provides a Java applet to enable remote media redirection. This may
be used in conjunction with the remote KVM feature, or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a
remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.
Once mounted, the remote device appears just like a local device to the server, allowing system
administrators or users to install software (including operating systems), copy files, update
BIOS, and so on, or boot the server from this device.
The following capabilities are supported:
The operation of remotely mounted devices is independent of the local devices on the
server. Both remote and local devices are useable in parallel.
Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the
server.
It is possible to boot all supported operating systems from the remotely mounted device
and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the
Tested/Supported Operating System List for more information.
Media redirection supports redirection for both a virtual CD device and a virtual
Floppy/USB device concurrently. The CD device may be either a local CD drive or else an
ISO image file; the Floppy/USB device may be either a local Floppy drive, a local USB
device, or else a disk image file.
78
Intel order number G64248-003
Intel® Server Board S1400SP TPS
Revision 2.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents