Setting The Flush Volume - Viega Eco Plus Instructions For Use Manual

Wc element
Table of Contents

Advertisement

X3
X2
X1
3.2.4

Setting the flush volume

Small flush volume
Large flush volume
Viega Eco Plus WC element
Lead empty pipe from the switch or button into the concealed cis-
tern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
X1= max. 0.75 m
n
n
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
X3= max. 4.75 m with two extension cables, 2 x article number 628
n
505
Immediate re-flushing of the flush volume is possible at the
factory settings.Ä 'Flush volume' on page 10
The WC element is factory-set at a small flush of approx. 3 l. The small
flush volume can be set from approx. 3 l to approx 2.5 l.
Remove the drain valve from the concealed cistern.
Push the slide control on the side of the overflow pipe to the desired
small flush volume:
Top position: approx. 2.5 l
n
Bottom position: approx. 3 l
n
The WC element is factory-set at a large flush volume of approx. 4.5 l.
The large flush volume can be set to approx. 6 l.
Remove the drain valve from the concealed cistern.