Timer settings

4
Timer settings
Timer configuration
12
Cause: Timer setting, this means the circulation is only
active if the operator activates this circulation for
bathing/swimming operation.
The operating status of your overall system can
change at any time during the automatic operation of
the controller. In this respect for example, the circu‐
lating pump, heating etc., can start or stop at any time.
The functions and operating times, circulation and backwashing
can be set at any time using via the timer setting.
[Actuator module] under [Options] , in operating
In operating mode
mode
[Circulation] the various timer adjustments can be made by
activating circulation.
When setting the timer, you must check that you save
the settings after each timer adjustment. If timers 1 ...
6 are set and then saved, then only timer 6 is saved.
There are 12 timer functions available for a pool circuit:
Timer 1 ... 6 when using Circulation 1
n
Timer 7 ... 12 when using Circulation 2
n
Timer adjustments with two circulating pumps
If two circulating pumps are connected, then they must
always be started simultaneously via the time. A
delayed switching on of the pumps, resulting in
switching on at different times, is not permitted
because this leads to an error message at the control
so that consequently the second circulating pump does
not start.
Example: Both circulating pumps are stopped by the
timer. The pool has status [Stop] and consequently the
paddle switch signals are not evaluated by the con‐
troller. If the timer now starts Circulating pump 1, then
within 30 seconds paddle switch [1] must deliver feed‐
back relating to the water flow. The paddle switch [2]
delivers the signal [no water flow] (which is indeed cor‐
rect), but the control reports the error [No flow]. Hence
the circulating pump [2] cannot be automatically
started by the timer.
Remedy: Adjust the timer so that both circulating
pumps are started simultaneously. This prevents one
of the two circulating pumps from not starting.
[continuous display] press the [ENTER] key
1.
In the
ð You can now see the
[Central menu item] display press the [F4] [CONFIG]
2.
In the
key
ð The configuration menu is now displayed.
3.
Using the horizontal arrow keys, select the
[F2] key [OPTION]
press the
ð You must now enter your password.
[Central menu item] .
[A] tab and then