Table of Contents

Advertisement

Quick Links

PROCESS AUTOMATION
MANUAL
POWERSCAN
PSCAN-D-1*

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs POWERSCAN PSCAN-D-1 Series

  • Page 1 PROCESS AUTOMATION MANUAL POWERSCAN PSCAN-D-1*...
  • Page 2 POWERSCAN With regard to the supply of products, the current issue of the following document is ap- plicable: The General Terms of Delivery for Products and Services of the Electrical In- dustry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 3: Table Of Contents

    POWERSCAN Safety ....................6 Validity .............................6 General safety instructions ......................6 Used Symbols..........................6 Delivery, Transport and Storage....................7 PSCAN-D-1* Intended use ......................7 Installation and Commissioning ....................7 Technical data barcode reader PSCAN-D-1* ................8 Identification barcode reader PowerScan PSCAN-D-1* ............8 Laser safety compliance ......................8 1.10 Repair and Maintenance......................9 1.11...
  • Page 4 POWERSCAN Parameter serial interface......................32 4.4.1 Baud Rate..........................32 4.4.2 Parity............................33 4.4.3 Data bits..........................34 4.4.4 Stop bits..........................34 4.4.5 Handshaking..........................35 4.4.6 ACK/NACK Protocol ......................35 4.4.7 FIFO............................36 4.4.8 Inter-Character Delay......................36 4.4.9 RX Timeout..........................36 4.4.10 Serial Trigger Lock .........................37 Data Format...........................37 4.5.1 Code Identifier ........................39 4.5.2 Custom Code Identifier ......................39 4.5.3 Header ...........................40 4.5.4 Terminator ..........................41...
  • Page 5 POWERSCAN References..................90 References RS232 Parameters.....................90 References Reading parameters...................91 References Decoding parameters ..................92 Codes and Character Sets............... 93 Single codes ..........................93 Code Identifier Table ......................94 Configuration Codes ......................96 Character Sets / Character Codes..................97 Maintenance and repair ..............99 Repair ............................99 Installation cable "Cable PSCAN-D-1D"...
  • Page 6: Safety

    The data sheet contains the electrical data of the Declaration of Conformity, the Certificate of Compliance and the EC-type-examination certificate. The documents mentioned are available from http://www.pepperl-fuchs.com or contact your local Pepperl+Fuchs representative.
  • Page 7: Used Symbols

    POWERSCAN Safety Used Symbols Safety-relevant Symbols Danger! This symbol indicates a warning about a possible danger. In case of ignoring the consequences may range from personal injury to death. Warning! This symbol indicates a warning about a possible fault or danger. In case of ignoring the consequences may cause personal injury or heaviest property damage.
  • Page 8: Delivery, Transport And Storage

    POWERSCAN Safety Delivery, Transport and Storage Check the packaging and contents for damage. Check if you have received every item and if the items received are the ones you ordered. Keep the original packaging. Always store and transport the device in the original packaging.
  • Page 9: Identification Barcode Reader Powerscan Pscan-D-1

    POWERSCAN Safety Identification barcode reader PowerScan PSCAN-D-1* PSCAN-D-1*-F2-* PSCAN-D-1*-R1-* Pepperl+Fuchs GmbH Pepperl+Fuchs, Inc. 68307 Mannheim, Germany Twinsburg, OH, USA BVS 09 ATEX E 075 Class I, II, III, Div 1 II 2G Ex ib [op is] IIB T4 Gb Group C - G, T4 II 2D Ex ib [op is] IIIB T135°C Db...
  • Page 10: Repair And Maintenance

    POWERSCAN Safety Labels cannot be attached to a laser diode. Hence the respective values are listed below: Laser Class 2M EN 60825-1 Laser diode Maximum output 0.9 mW Wavelength 630 - 680 nm according to class 2 EN 60825-1 and CDRH 21CFR 1040 1.10 Repair and Maintenance...
  • Page 11: Product Specifications

    POWERSCAN Product Specifications Product Specifications PSCAN-D-1* Function The EX barcode reader PSCAN-D-1* can be used in hazardous areas Zone 1 and Zone 21 according to the directive 94/9/EG (ATEX) as well as Class I/Div 1 and Class II/Div 1 (ANSI/UL 913-2008). (depending on version) The barcode reader is able to read all standard 1D code families.
  • Page 12: Device Components

    POWERSCAN Product Specifications Note! To get a good reading performance do not hold the barcode reader vertically, use the reading angles in the figure below. Device components Barcode reader + connecting cable consisting of a helix cable 5 m and a male 5-pin connector (M12 connector) mounted.
  • Page 13 POWERSCAN Product Specifications Figure 2.1Reading characteristics PSCAN Dimensions Dimensions male 5-pin connector (M12 connector)
  • Page 14 POWERSCAN Product Specifications PSCAN-D-1* General specifications Readable codes 2/5 Family, Code 39, (plus Code 32, Clip 39), EAN/UPC, EAN 128, Code 128, Code 93, CODABAR, Code 49, Code MSI, Code 11, Code 16K, ISBN/ISSN, ISBT 128, GS1DataBar (once RSS) Laser class Class 2 - EN 60825-1, CDRH Scan rate 30 ...
  • Page 15: Holder For Barcode Reader

    POWERSCAN Product Specifications Accessory PSCAN-D-1* Accessory Order designation Order number Connecting cable S-ENT/PC-9 520645 (PC --- ENT-DC) Connecting cable DATL-A4-0 (different, depending on the (Box-A9 --- ENT-DC) cable length) Holder for barcode reader Scanner-Holder-VisuNet- 208140 RM/PC Replacement cable for SPAREPARTS-PSCAN-D- 242867 barcode reader EX-CABLE...
  • Page 16: Connecting Cable Pscan-D-1D

    POWERSCAN Product Specifications 2.4.2 Connecting cable PSCAN-D-1D The connecting cable PSCAN-D-1D is a cable for replacement for the barcode reader PSCAN-D-1*. The mounting instruction you'll find in chaptersee chapter 7.2. M12 connector, male 5-pin Connector RJ12 (6 pin)
  • Page 17: Ex I Junction Box With Holder For Barcode Reader (Box-A9-Pscan-F2-N)

    POWERSCAN Product Specifications 2.4.3 Ex i junction box with holder for barcode reader 2.4.4 (BOX-A9-PSCAN-F2-N) Dimensions Figure 2.2Abmessungen BOX-A9-PSCAN-F2-N...
  • Page 18: Installation

    2. Check that all items are present and correct based on your order and the shipping documents. If you have any questions, please contact Pepperl+Fuchs. 3. Keep the original packing material in case you need to store or ship the unit at a later time.
  • Page 19: Connecting The Barcode Reader Pscan-D-1* Via Ipc-Ex

    POWERSCAN Installation 3.2.2 Connecting the barcode reader PSCAN-D-1* via iPC-EX 3.2.3 Connecting the barcode reader PSCAN-D-1* to a Host (PC) via TERMEX With this application please contact the support.
  • Page 20: Connecting The Barcode Reader Pscan-D-1* Via Visunet

    POWERSCAN Installation 3.2.4 Connecting the barcode reader PSCAN-D-1* via VisuNet Electrical Installation PSCAN-D 3.3.1 Connecting cable ENT-DC to PC Pin assignment 9pol SubD 9pol SubD female female n.u. n.u. n.u.
  • Page 21: Status Indicators

    POWERSCAN Installation 3.3.2 Status Indicators The barcode reader has two indicator LEDs, a good read spot and a beeper. They signal several operating conditions which are descriped in the table below. high tone low tone Tone and intensity are user-configurable. The data entry "good read tone"...
  • Page 22: Installation Box-A9-Pscan-F2

    POWERSCAN Installation Installation BOX-A9-PSCAN-F2 BOX-A9-PSCAN-F2-N 1. Connecting socket M12 x 5 2. Equipotential bonding (connecting bolt M6) 3. Cable gland M16 x 1,5 Danger! danger of explosion In the event the warning is ignored, the consequences may range from personal injury to death.
  • Page 23 POWERSCAN Installation Figure 3.1Equipotential bonding BOX-A9-PSCAN 1 washer 2 lock washer 3 screw nut M4 4 cable lug Installation cable DATL-A4-0 (max. length: 150 m) (Connection ENT-DC --- BOX-A9-PSCAN-F2-N) Clamp the cable to the terminal as follows: DATL-A4-0 Figure 3.2BOX-A9-PSCAN-F2-N via connecting cable DATL-A4-0 to ENT-DC...
  • Page 24: Mounting The Holder For Barcode Reader

    POWERSCAN Installation Additional information Klemmenbelegung BOX-A9-PSCAN ENT-DC BOX-A9-PSCAN 1 2 3 4 PSCAN (X)cable Pin assignment Box-A9-PSCAN Colour Clamp Signal Blue White Black Grey + brown Mounting the holder for barcode reader 13 edge protection...
  • Page 25 POWERSCAN Installation Hole pattern holder for barcode reader Holder for barcode reader, top view...
  • Page 26 POWERSCAN Installation distance plate washer M3 lock washer M3 hex nut gasket adapter (bracket) countersunk head screw M4 (2x). washer M4 (2x) nut M4 (2x) nut M4 (2x) holder for barcode reader countersunk head screw M5 (2x) Contact holes 1. Contact 2 holes for fastening the holder for barcode reader (2x Ø 4.5). 2.
  • Page 27 POWERSCAN Installation Installing the earth stud Danger! danger of explosion In the event the warning is ignored, the consequences may range from personal injury to death. Connect the earth stud with the equipotential bonding of the system. (cross section min. 4...
  • Page 28 POWERSCAN Configuration PSCAN-D-1* Configuration PSCAN-D-1* There are 2 different configurations for the barcode reader. Configurations for the barcode reader PSCAN-D-1* Version type: PSCAN-D-1*-**-05 Version type: PSCAN-D-1*-**-20 for devices of the product line TERMEX for devices of the product lines VisuNet Ex1 RM/PC, VisuNet Ex1 KM (iPC-Ex), ENT-DC Configuring PSCAN-D-1*-**-05 Configure the barcode reader...
  • Page 29 POWERSCAN Configuration PSCAN-D-1* Configuring PSCAN-D-1*-**-20 Configure the barcode reader 1. Read the following codes in the given sequence and follow the instructions. 2. Read "Enter configuration" 3. Read 9600 Baud (*) 4. Read Parity EVEN 5. Read Aiming System enable 6.
  • Page 30: Configuration Pscan-D-1

    POWERSCAN Configuration PSCAN-D-1* PSCAN-D-1* default configuration Restore PSCAN-D default Default serial interface Parameter Default Baud Rate 9600 Parity disabled Data Bits Stop Bits Handshaking disabled ACK/NAK Protocol disabled FIFO enabled Inter-Character Delay disabled Rx Timeout 5 sec Serial Trigger Lock disabled Default Data Format Parameter...
  • Page 31 POWERSCAN Configuration PSCAN-D-1* Default Reading Parameter Flash Mode on 1 sec., off 0,6 sec. Reads per cycle Safety time 0.5 sec. Beeper intensity High intensity Beeper tone Ton 2 Beeper type Monotone Beeper length Short Good read spot duration Medium Aiming system Disabled Default Decoding Parameters...
  • Page 32: Parameter Serial Interface

    POWERSCAN Configuration PSCAN-D-1* Delivery status PSCAN-D: Serial interface Parameter Delivery status 5 mA (Terminal (TERMEX) 20 mA (ENT-DC / VisuNet connection) connection) Baud-Rate 1200 9600 Parity EVEN EVEN Data bits Stop bit Parameter serial interface Default serial interface Parameter Default Baud Rate 9600 Parity...
  • Page 33 POWERSCAN Configuration PSCAN-D-1* 4.4.1 Baud Rate Enter configuration Exit and save configuration Baud Rate 300 Baud 600 Baud 1200 Baud 2400 Baud 4800 Baud 9600 Baud (*) 19200 Baud 38400 Baud...
  • Page 34: Parity

    POWERSCAN Configuration PSCAN-D-1* 4.4.2 Parity Enter configuration Exit and save configuration Parity Parity disabled (*) Parity even Parity odd 4.4.3 Data bits Enter configuration Exit and save configuration Data bits 7 Data bits 8 Data bits (*) 9 Data bits...
  • Page 35: Stop Bits

    POWERSCAN Configuration PSCAN-D-1* 4.4.4 Stop bits Enter configuration Exit and save configuration Stoppbit 1 Stop bit (*) 2 Stop bits 4.4.5 Handshaking Enter configuration Exit and save configuration Handshaking Transmission without handshaking (*) Hardware RTS/DTR Software XON/XOFF RTS always on...
  • Page 36: Ack/Nack Protocol

    POWERSCAN Configuration PSCAN-D-1* 4.4.6 ACK/NACK Protocol Enter configuration Exit and save configuration ACK/NACK Protocol disable (*) enable 4.4.7 FIFO Enter configuration Exit and save configuration FIFO disable enable (*) 4.4.8 Inter-Character Delay Enter configuration Exit and save configuration Inter-Character Delay Inter-Character delay Read 2 numbers from the table where (Delay between characters transmitted to...
  • Page 37: Rx Timeout

    POWERSCAN Configuration PSCAN-D-1* 4.4.9 RX Timeout Enter configuration Exit and save configuration RX Timeout Timeout control in reception from Host Read 2 numbers from the table where 00 = Timeout disabled 50 = RX timeout 5 sec (*) 01-99 = Timeout from 0.1 bis 9.9 seconds 4.4.10 Serial Trigger Lock Enter configuration...
  • Page 38 POWERSCAN Configuration PSCAN-D-1* To change the default values 1. Read the "Enter Configuration" code once. 2. Read configuration codes from the desired groups or follow the procedure given for this code group. 3. When desired you can change further configuration codes directly. 4.
  • Page 39: Code Identifier

    POWERSCAN Configuration PSCAN-D-1* Code AIM Standard Datalogic Standard Custom Code 11 Code 16 K Code 49 GS1 DataBarTM Expanded and Stacked GS1 DataBar Limited GS1 DataBar 14 Linear and Stacked Reference AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not definded.
  • Page 40: Custom Code Identifier

    POWERSCAN Configuration PSCAN-D-1* 4.5.2 Custom Code Identifier Enter configuration Exit and save configuration Custom code identifier Default: disabled Define costom code identifiers 1.) Read the left code (EH). 2.) Select the code type from the code table in for the identifier you want to change. 3.) You can define 1 or 2 identifier characters for each code type.
  • Page 41 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration four character header five character header six character header seven character header eight character header After selecting one of the desired Header codes, read the character(s) from the Hex table. Valid characters are in the range 00- Example: four character header: + 41 42 43 44 = Header ABCD...
  • Page 42: Terminator

    POWERSCAN Configuration PSCAN-D-1* 4.5.4 Terminator Enter configuration Exit and save configuration Terminator no terminator (*) one character terminator two character terminator three character terminator four character terminator five character terminator six character terminator seven character terminator eight character terminator After selecting one of the desired Header codes, Terminator codes, read the character(s) from the Hex table.
  • Page 43: Field Adjustment

    POWERSCAN Configuration PSCAN-D-1* 4.5.5 Field adjustment Enter configuration Exit and save configuration Field adjustment Default: disabled (*) 1.) To define the field adjustment (enable) 2.) Read the enable field adjustment code:see chapter 6.2 3.) Select the type of adjustment to perform right addition left addition right deletion...
  • Page 44: Field Adjustment Character

    POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Example: To add 4 characters to the right of Standard Code 39 Codes: 4.5.6 Field Adjustment character Enter configuration Exit and save configuration Field Adjustment character Default: disabled (*) 1.) Read the field adjustment character 2.) Read the hexadecimal value code corresponding to the character you want to...
  • Page 45: Code Length Tx

    POWERSCAN Configuration PSCAN-D-1* 4.5.7 Code Length Tx Enter configuration Exit and save configuration Code Länge Tx not transmitted (*) transmitted in variable-digit format transmitted in fixed 4-digit format 4.5.8 Character Replacement Enter configuration Exit and save configuration Character Replacement disable character replacement (*) This parameter allows up to three characters to be replaced from the barcode read.
  • Page 46 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration 2.) From the Code Identifier Table, read the Code Identifier for the desired code family see chapter 6.2 0 = character replacement will be effective for all code families. 3.) Read two characters corresponding to the Hex value (00-FE), which identifies the character to be replaced.
  • Page 47: Power Save

    POWERSCAN Configuration PSCAN-D-1* Power Save Der Defaultwert ist mit (*) gekennzeichnet: Default Power save Parameter Default Sleep state disable Enter sleep timeout 0,6 sec. Der Defaultwert ist mit (*) gekennzeichnet: To change the default values 1. Read the "Enter Configuration" code once. 2.
  • Page 48: Enter Sleep Timeout

    POWERSCAN Configuration PSCAN-D-1* 4.6.2 Enter Sleep Timeout Enter configuration Exit and save configuration Enter sleep timeout Enter sleep timeout Read 2 numbers n the range 00-99: 00 = Enter sleep state immediately. 01 - 99 = corresponds to a max. 9.9 sec. delay before entering the sleep state.
  • Page 49: Reading Parameters

    POWERSCAN Configuration PSCAN-D-1* Reading Parameters Default Reading Parameter Parameter Default Trigger type Hardware trigger Trigger signal Trigger active level Trigger click Disabled Trigger-off timeout Disabled Flash Mode on 1 sec., off 0,6 sec. Reads per cycle Safety time 0.5 sec. Beeper intensity High intensity Beeper tone...
  • Page 50: Trigger Signal

    POWERSCAN Configuration PSCAN-D-1* 4.7.2 Trigger Signal Enter configuration Exit and save configuration Trigger Signal Trigger active level (*) Trigger active pulse See chapter 5.2 4.7.3 Trigger Click Enter configuration Exit and save configuration Trigger Click disable (*) enable See chapter 5.2...
  • Page 51: Trigger-Off Timeout

    POWERSCAN Configuration PSCAN-D-1* 4.7.4 Trigger-off Timeout Enter configuration Exit and save configuration Trigger-off Timeout Default: disabled (*) Trigger-off Timeout changes Read 2 numbers in the range 00-99: 00 = disabels the trigger-off timeout (*) 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically.
  • Page 52: Reads Per Cycle

    POWERSCAN Configuration PSCAN-D-1* 4.7.6 Reads per cycle Enter configuration Exit and save configuration Reads per cycle One read per cycle (*) Multiple reads per cycle See chapter 5.2 4.7.7 Safety Time Enter configuration Exit and save configuration Safety Time Default Safety time 0.5 sec. (*) Safety Time Read 2 numbers in the range 00-99: 00 = no same code consecutive reading...
  • Page 53: Beeper Intensity

    POWERSCAN Configuration PSCAN-D-1* 4.7.8 Beeper Intensity Enter configuration Exit and save configuration Beeper Intensity Beeper off Low intensity Medium intensity High intensity (*) 4.7.9 Beeper Tone Enter configuration Exit and save configuration Beeper Tone Tone 1 Tone 2 (*) Tone 3 Tone 4...
  • Page 54: Beeper Type

    POWERSCAN Configuration PSCAN-D-1* 4.7.10 Beeper Type Enter configuration Exit and save configuration Beeper Type monoton (*) bitonal 4.7.11 Beeper length Enter configuration Exit and save configuration Beeper length long short...
  • Page 55: Good Read Spot Duration

    POWERSCAN Configuration PSCAN-D-1* 4.7.12 Good read spot duration Enter configuration Exit and save configuration Good read spot duration disable short medium (*) long 4.7.13 Aiming System Enter configuration Exit and save configuration Aiming System disabled (*) enabled...
  • Page 56: Decoding Parameters

    POWERSCAN Configuration PSCAN-D-1* Decoding Parameters Default Decoding Parameters Parameter Default Ink Spread enabled Overflow Control enabled Interdigit Control enabled Decoding Safety one read Puzzle Solver disabled The Default value is signed with (*). Caution! Malfunciton of the barcode reader With changing this parameters the reading performance can be degraded or increase the possibility of a decoding error.
  • Page 57: Overflow Control

    POWERSCAN Configuration PSCAN-D-1* 4.8.2 Overflow Control Enter configuration Exit and save configuration Overflow Control disable enable (*) See chapter 5.3 4.8.3 Interdigit Control Enter configuration Exit and save configuration Interdigit Control disable enable (*) See chapter 5.3...
  • Page 58: Decoding Safety

    POWERSCAN Configuration PSCAN-D-1* 4.8.4 Decoding Safety Enter configuration Exit and save configuration Decoding Safety one read (*) two reads three reads four reads 4.8.5 Puzzle Solver Enter configuration Exit and save configuration Puzzle Solver disable (*) enable...
  • Page 59: Code Selection

    POWERSCAN Configuration PSCAN-D-1* Code Selection Default Code selection Parameter Default EAN /UPC - Family EAN 8/EAN 13 / UPC A/UPC E Check digit control no conversion 2/5 Family Interleaved 2/5 Check digit control and transmission variable code length: 4-55 characters Code 39 Family Standard Code 39 no check digit control...
  • Page 60: Code Selection: Manual Configuration

    POWERSCAN Configuration PSCAN-D-1* Follow the given procedure to auto-configure the desired code families Caution! Failure The barcode reader is unable to read codes. During the auto configuration procedure you must read a code. If no code is read the configuration will be empty and therefore the reader will be unable to read codes. 1.
  • Page 61 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Code selection Disable all code families Note! The reader allows up to 10 code selections. This does not limit the number of CODES enabled to 10, as it depends on the code family. Single selection = ONE combination code from the EAN family...
  • Page 62 POWERSCAN Configuration PSCAN-D-1* EAN/UPC - Family Enter configuration Exit and save configuration EAN/UPC - FAMILY disable the family EAN/UPC EAN 8/EAN 13/UPC A/UPC E with and without ADD ON without ADD ON EAN 8/EAN 13/UPC A/UPC E (*) EAN 8/EAN 13 UPC A/UPC E with ADD ON 2 and 5 EAN 8/EAN 13/UPC A/UPC E...
  • Page 63 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration EAN 8/EAN 13 UPC A/UPC E with ADD ON 5 only EAN 8/EAN 13 UPC A/UPC E with and without ADD ON EAN/UPC with and without ADD ON no EAN/UPC autodiscrimination ADD ON by autodiscrimination (*) prefix...
  • Page 64 POWERSCAN Configuration PSCAN-D-1* SELECT EAN/UPC PREFIXES Note! When scanning the following codes, barcodes starting with the selected prefixes will be read and transmitted only if the ADD ON is present. If no ADD on is found, the barcode will not be read. Barcodes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON.
  • Page 65 POWERSCAN Configuration PSCAN-D-1* Example The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the 434/439, 977 and 978 prefixes. 1. EAN/UPC Autodiscrimination ADD ON by Prefix. 2. 434/439: enables reading and transmission with ADD ON of all EAN/UPC barcodes start- ing with 434/439 prefixes.
  • Page 66 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration EAN/UPC CHECK DIGIT TX SELECTIONs For each code type in this family you can choose to transmit the check digit or not. EAN 8 Check Digit Transmission disabled enabled (*) EAN 13 Check Digit Transmission disabled enabled (*) UPC A Check Digit Transmission...
  • Page 67 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Enable only ISBN Enable only ISSN Enable ISBN and ISSN Disable ISBN and ISSN 2/5 - Family Enter configuration Exit and save configuration 2/5 - FAMILY disable the Family 2/5 • Read the desired family code. Interleaved 2/5 (*) Normal 2/5 (5 Bars) Industrial 2/5 (IATA)
  • Page 68 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration no check digit control check digit control and transmission check digit control without transmission • Read 4 numbers for the code length where: First 2 digits = minimum code length Second 2 digits = maximus code length The maximum code length is 99 characters.
  • Page 69 POWERSCAN Configuration PSCAN-D-1* Code 39 - Family Enter configuration Exit and save configuration Code 39 - FAMILY disabled the Code 39 family • Read the desired family code. Standard Code 39 (*) Full ASCII Code 39 • Read a check digit selection no check digit control (*) Check digit control and transmission Check digit control without transmission...
  • Page 70 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Code Length optional The code length selection is vaild for the entire Code 39 family Set Code length Read the code + 4 numbers for the code length where First 2 digits = minimum code length Second 2 digits = maximum code length The maximum code length is 99 characters.
  • Page 71 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration disable (*) enable Code length optional The code length selection is valid for the entire 128 family. Set code length Read the code +4 numbers for the code length where: First 2 digits = minimum code length Second digits = maximum code length The maximum code length is 99 characters.
  • Page 72 POWERSCAN Configuration PSCAN-D-1* Codabar Family Enter configuration Exit and save configuration Standard Codabar • Read the desired equality control code. Standard Codabar Standard Codabar no start/stop character equality control Start/stop character equality control • Read a start/stop transmission selection no transmission transmission Codabar ABC Codabar ABC forced concatenation...
  • Page 73 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Start / Stop character case in transmission transmit start/stop characters in lower case transmit start/stop character in upper case MSI - Family Enter configuration Exit and save configuration disable the family MSI (*) Enable the code by selecting one of the check digit selections.
  • Page 74 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration MOD 11 - MOD 10 with tx MOD 10 - MOD 10 no tx MOD 10 - MOD 10 with tx Code 11 Enter configuration Exit and save configuration Code 11 disable the Code 11 family (*) Enable the code by selecting one of the check digit selections.
  • Page 75 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Type K no tx Type C and type K with tx Type C and type K no tx Code 16K Enter configuration Exit and save configuration Code 16K disable Code 16K (*) enable Code 16K Code 49 Enter configuration...
  • Page 76 POWERSCAN Configuration PSCAN-D-1* Code GS1 Databar Code Family Enter configuration Exit and save configuration Code GS1 Databar Code Family disabled GS1 Databar Code Family (*) GS1 Databar Expanded Linear and Stacked disabled enabled GS1 Databar limited disabled enabled GS1 Databar Linear and Stacked disabled enabled...
  • Page 77: Advanced Formatting

    POWERSCAN Configuration PSCAN-D-1* 4.10 Advanced Formatting Default Advanced Formatting Parameter Default Concatenation disabled Advanced Formatting no Advanced Formatting enabled The Default value is signed with (*) To change the "Advanced Formatting" Default values 1. Read the "Enter Configuration" code once. 2.
  • Page 78 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Define Concatenation Code 2 Code ID Read the code type from the Code Identifier table. Code length Read an number in the range 0-99 from the Hex/Numeric table. Concatenation Result Code ID Since you can concatenate codes from different families, you must select the Code ID character of the resulting code.
  • Page 79 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration no code transmitted after Timeout only code 1 transmitted (if read) after timeout Only code 2 transmitted (if read) after Either code 1 or code 2 transmitted after timeout timeout...
  • Page 80 POWERSCAN Configuration PSCAN-D-1* 4.10.2 Advanced Formatting Advanced Formatting Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria, which you will define in the following procedure.
  • Page 81 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Step 1 Begin Format Definition Begin format 1 definition Begin format 2 definition Begin format 3 definition Begin format 4 definition Step 2 Match Code Type Match Code Type or any code type Read the above code + the code type to match from the Code Identifier Table see chapter 6.2 .
  • Page 82 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Match with a 3-character string Match with a 4-character string After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 00 to FE Example Match Code with the 2-character predefined string ="@@"...
  • Page 83 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Step 6 Define Code Fields Each code field length can be set by either: Defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field.
  • Page 84 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration or 4.) this is the last field (variable length) and Field 1 Terminators no field terminators 1 field terminator 2 field terminators Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00 to FE.
  • Page 85 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration or 3.) Field length Read two numbers in the range 01 to 99 to define the field length. or 4.) this ist the last field (variable length) and Field 2 Terminators no field terminators 1 field terminator 2 field terminators...
  • Page 86 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration or 2.) Match character Read the match character from the HEX table. Range of character = 00 bis FE or 3.) Field length Read two numbers in the range 01 to 99 to define the field length.
  • Page 87 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration discard separator include separator or 2.) Match character Read the match character from the HEX table. Range of the characters = 00 bis FE or 3.) Field length Read two numbers in the range 01 to 99 to define the field length.
  • Page 88 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Define Field 5 by either 1.) Field separator Read the field separator character form the HEX table. Range of characters= 00 to FE. discard separator include separator or 2.) Match character Read the match character from the HEX tabel.
  • Page 89 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration 1 Field terminator 2 Field terminators Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00 to FE. Step 7 First additional Fixed Field no fixed field 1 character fixed field 2 character fixed field...
  • Page 90 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration no fixed field 1 character fixed field 2 character fixed field 3 character fixed field 4 character fixed field 5 character fixed field 6 character fixed field Step 9 Field Transmission Number of fields to transmit Read one number in the range 1 to 7 for the number of fields to transmit.
  • Page 91 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Field 3 Field 4 Field 5 additional field 1 additional field 2 Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. + 4 + Step 10 Standard Formatting Do not apply Standard Formatting...
  • Page 92 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration End Format 1 Definition End Format 2 Definition End Format 3 Definition End Format 4 Definition Enable Advanced Format No Advanced Formats enabled (*) Advanced Format 1 enable Advanced Format 1 disable Advanced Format 2 enable Advanced Format 2 disable Advanced Format 3 enable...
  • Page 93 POWERSCAN Configuration PSCAN-D-1* Enter configuration Exit and save configuration Clear data - no transmission transmit data using standard format Codes not matching can be ignored, cleared from memory not transmitted. Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).
  • Page 94: References

    POWERSCAN References References References RS232 Parameters Handshaking Handshaking Software-Handshaking (XON/XOFF) During transmission between Cradle and Host, it the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received. ACK/NACK PSCAN-D-1 This parameter sets a transmission protocol in which the Host responds to the reader after...
  • Page 95: References Reading Parameters

    POWERSCAN References Figure 5.1ACK/NACK enabled References Reading parameters Trigger Signal This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected: • Trigger acive level: the reader goes (ON), when the trigger is pressed and goes OFF when it is released.
  • Page 96: References Decoding Parameters

    POWERSCAN References Safety Time Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to remove from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code.
  • Page 97: Codes And Character Sets

    POWERSCAN Codes and Character Sets Codes and Character Sets Single codes • To enter numerical values, scan successively the digits 0-9. • Read alphanumeric values by scanning their hex values. I.E. 'L' (hexadecimal value: 4C): first scan '4' then 'C'.
  • Page 98: Code Identifier Table

    POWERSCAN Codes and Character Sets Code Identifier Table 2/5 Interleaved 2/5 Industrial 2/% normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 mit 2 ADD ON EAN 8 mit 5 ADD ON...
  • Page 99 POWERSCAN Codes and Character Sets EAN 13 mit 2 ADD ON EAN 13 mit 5 ADD ON UPC A mit 2 ADD ON UPC A mit 5 ADD ON UPC E mit 2 ADD ON UPC E mit 5 ADD ON Code 39 Code 39 Full ASCII Codabar...
  • Page 100: Configuration Codes

    POWERSCAN Codes and Character Sets ISBT 128 Code 16K Code 11 Code 49 GS1 Databar Expanded Linear and Stacked GS1 Databar Limited GS1 Databar 14 Linear and Stacked Configuration Codes Enter configuration Exit and save configuration Abort current setting Cancel all current settings (without exit) Send Firmware Version Restore Default...
  • Page 101 POWERSCAN Codes and Character Sets Hexa- Hexa- Hexa- Decimal decimal Character Decimal decimal Character Decimal decimal Character 20 h SPACE 40 h 60 h 21 h 41 h 61 h 22 h 42 h 62 h 23 h 43 h 63 h 24 h 44 h...
  • Page 102 POWERSCAN Codes and Character Sets ASCII control characters Meaning of the most important Control Decimal Hexadecimal Character characters 00 h without effect 01 h Start of header 02 h Start of text 03 h End of text 04 h End of transmission 05 h Enquiry 06 h...
  • Page 103: Maintenance And Repair

    Maintenance and repair Maintenance and repair Repair The devices must not be repaired, changed or manipulated. Please contact your local Pepperl+Fuchs sales representative for further instructions. Installation cable "Cable PSCAN-D-1D" to barcode reader PSCAN-D-* Exchange of the cable on barcode reader PSCAN-D-1* 7.2.1...
  • Page 104: Removing Old Cable At The Pscan-D-1

    POWERSCAN Maintenance and repair 7.2.2 Removing old cable at the PSCAN-D-1* Removing old cable 1. Make sure that the barcode reader is disconnected from the mains during installation. 2. Unscrew the screw at the barcode reader. 3. First slide down the strain relief and then the cover over the yellow "tooth". Slide down the cable spacer.
  • Page 105: Connecting The New Cable

    POWERSCAN Maintenance and repair 7.2.3 Connecting the new cable Figure 7.1(1) rubber gasket (2) plastic boot (3) cable spacer (4) cover (5) strain relief Install the new cable on the barcode reader 1. Make sure that the barcode reader is disconnected from the mains during installation. 2.
  • Page 106 POWERSCAN Maintenance and repair 4. Insert the cable into the socket of the plastic boot (2) with the rubber gaskett (1). Ensure that the "FRONT" markting on the plastic boot (2) is facing out. 5. Insert the cable with the plastic boot (2) and gasket (1) into the handle. Ensure that the "FRONT"...
  • Page 107 POWERSCAN Maintenance and repair (3) cable spacer 7. Push the cover (4) along the cable towards the reader, and hook it over the yellow "tooth". 8. Insert the strain relief (5) into the cover (4) and tighten the screw to fix the whole assembly to the reader handle.
  • Page 108: Pscan-D-1* Non Ex

    Technical data of the barcode reader PSCAN-D-1D-NO-R2-N: please refere to the datasheet of the company Datalogic "PowerScan D8330". The interface of the barcode reader is compatible to the Pepperl+Fuchs NON EX devices with the interface RS 232. (e. g. operator panel: TERM)
  • Page 109: Cable With Socket 8-Pin

    POWERSCAN PSCAN-D-1* NON EX M12 Connector 8-pin Connector RJ12 8.3.2 Cable with socket 8-pin...
  • Page 110 POWERSCAN PSCAN-D-1* NON EX Socket Terminalassignment Operator panel TERM grün / green braun / brown Buchse / TERM gelb / yellow socket 8-pin weiß / white...
  • Page 111: Appendix

    RS 232 interface Version Version 1.0 Option no option customised Not all features can be combined. Please contact your local Pepperl+Fuchs partner. Connection PSCAN-D-1* to a 4-pin socket (devices in previous versions) Accessory Order designation Order number Adapter cable...
  • Page 112: Certifications

    POWERSCAN Appendix Certifications Declaration of Conformity Pepperl+Fuchs EC-Type Examination CertificateBVS 09 ATEX E 075 Declaration of Conformity for special conditions for the installation in zone 22...
  • Page 123 Pepperl+Fuchs Datenblatt und der gültigen Pepperl+Fuchs Betriebsanleitung. This Statement of Conformity is only valid in connection with the valid datasheet of Pepperl+Fuchs and the valid instruction of Pepperl+Fuchs. ___________________________________________________________ Die Pepperl+Fuchs GmbH, Lilienthalstr. 200, 68307 Mannheim, Deutschland erklärt hiermit in alleiniger Verantwortung, dass das oben genannte Produkt den Anforderungen gemäß...
  • Page 126 PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim · Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/pfcontact www.pepperl-fuchs.com Subject to modifications 218221 / DOCT-1791F Copyright PEPPERL+FUCHS • Printed in Germany 02/2015...

Table of Contents