When floor drying is active on a circuit, all other circuits (e.g. DHW)
are shut down. The use of this function is only possible on circuits B
and C.
STOP DRYING TEMP
A
START DRYING TEMP
Z
Today
E
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
For example
A
STOP DRYING TEMP: 47 °C
Z
START DRYING TEMP: 20 °C
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
Every day at midnight (00:00): the set point (START
DRYING TEMP) is recalculated and the remaining number
of days (NB DAYS DRYING) is decremented.
n ROOM S.INFL
Used to adjust the influence of the room sensor on the water
temperature for the circuit concerned.
No influence (remote control fitted in a location with no influence)
0
Slight influence
1
Average influence (recommended)
3
10 Room thermostat type operation
n NIGHT
This parameter is displayed if at least one circuit does not
include a room sensor.
For circuits without a room sensor:
4 NIGHT :DEC. (Reduced): The reduced temperature is maintained
during reduced periods. The circuit pump operates constantly.
4 NIGHT :STOP (Stop): Heating is shut down during reduced
periods. When installation antifreeze is active, the reduced
temperature is maintained during reduced periods.
5. Operating the appliance
44