VFD Wiring Schematic

Typical wiring schematic for a VFD is shown in
Unit specific wiring schematics are shipped with each unit.
Figure 40. Typical VFD wiring schematic
L1
L2
L3
1Q1
4A
5A
6A
BLK
RED
208V
1T1
24V
BLU
YEL
196001410003-60
196001410003-61
BLK
ORG
BLK
BLK/RED
230V
460V
1T1
1T1
24V
24V
BLU
YEL
BLU
YEL
CLCH-SVX009A-EN
Figure
1X1
6B
6A
RED
5B
5A
BLK
4B
4A
196001410003-39
196001410003-40
196001410003-42
5
196001410003-41
BLK
RED
575V
1T1
5
24V
BLU
YEL
INSET B
NOTES:
1. UNLESS OTHERWISE NOTED ALL SWITCHES ARE
SHOWN AT 25
PRESSURE, AT 50% RELATIVE HUMIDITY, WITH ALL
UTILITIES TURNED OFF, AND AFTER A NORMAL
SHUTDOWN HAS OCCURED.
2. DASHED LINES INDICATE RECOMMENDED FIELD
WIRING BY OTHERS.
AND/OR DASHED DEVICE OUTLINES INDICATE
COMPONENETS PROVIDED BY THE FIELD. PHANTOM
LINE ENCLOSURES INDICATE ALTERNATE CIRCUITRY
OR AVAILABLE SALES OPTIONS.
INDICATE WIRING BY TRANE.
3. NUMBERS ALONG THE RIGHT SIDE OF THE SCHEMATIC
DESIGNATE THE LOCATION OF CONTACTS BY LINE
NUMBER.
NORMALLY CLOSED CONTACT.
BELOW THE LINE NUMBER POINTING UPWARD INDICATES
A TIMED CONTACT WHICH BEGINS TIMING WHEN
ENERGIZED.
4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH
THE NATIONAL ELECTRICAL CODE, STATE, AND
LOCAL REQUIREMENTS.
APPLICABLE NATIONAL AND/OR LOCAL REQUIREMENTS
SHALL APPLY.
INSULATION RATING NOT LESS THAN 600V COPPER
CONDUCTORS ONLY.
5
CONTROL TRANSFORMER SHOWN FOR 208V PRIMARY.
FOR 230V, 460V, OR 575V PRIMARY REFER TO INSET "B".
6
FAULT RELAY CONTACTS STATE SHOWN WITH DRIVE
CONTROLLER DE-ENERGIZED OR FAULTED.
40.
DEVICE
DESCRIPTION
1Q1
UNIT DISCONNECT SWITCH
1T1
CONTROL TRANSFORMER
1X1
POWER DISTRIBUTION BLOCK
2M1
9F1
9F2
9F3
9T1
9F1
6C
7A
L3
9F2
5C
8A
L2
9F3
4C
9A
L1
403B
18
RUN
404B
12
+24VDC
409B
53
REF IN
410B
55
COM
W/98
18A
C (77
F), AT ATMOSPHERIC
DASHED LINE ENCLOSURES
SOLID LINES
AN UNDERLINED NUMBER INDICATES A
AN OPEN ARROWHEAD
OTHER COUNTRIES
FIELD CONDUCTORS SHALL HAVE
Electrical Requirements
ZONE
15
31
20
MOTOR 1
43
VFD FUSE
20
VFD FUSE
22
VFD FUSE
24
VFD
20
9T1
400A
GND
401B
401B
COMM5+
68
402B
402B
COMM5-
69
FAULT+
01
407B
408B
FAULT-
02
V/97
U/96
15A
12A
SPLICE
12B
12A
SPLICE
15B
15A
SPLICE
18B
18A
VFD FUSE - 9F1, 9F2, 9F3
VOLTAGE
MOTOR HP
FUSE
CLASS
208/230
1
LP-CC-10
208/230
1.5, 2
LP-CC-10
208/230
3
LP-CC-25
208/230
5
JJN-50
208/230
7.5
JJN-50
208/230
10
JJN-80
208/230
15
JJN-100
460
1
LP-CC-10
460
1.5, 2
LP-CC-10
460
3
LP-CC-15
460
5
LP-CC-15
460
7.5
LP-CC-25
460
10
LP-CC-25
460
15
JJS-50
575
1, 1.5, 2, 3
LP-CC-20
575
5
LP-CC-20
575
7.5
LP-CC-20
575
10
LP-CC-20
575
15
LP-CC-30
DEVICE PREFIX LOCATION CODE
AREA
LOCATION
1
MAIN CONTROL PANEL
2
SUPPLY FAN & COIL SECTION
3
ELECTRIC HEAT CONTROL BOX
4
FILTER SECTION
5
MIXING BOX SECTION
6
COIL ACCESS SECTION
7
EXTERNAL PIPING
8
FIELD INSTALLED DEVICE
9
VFD CONTROL PANEL
196001410003-46
196001410003-45
196001410003-44
6
196001410003-43
2M1
M
3
CC
CC
CC
T
T
T
T
CC
CC
CC
CC
CC
CC
T
CC
CC
CC
CC
CC
45