Trane TWE031E13FB1 Installer's Manual

Trane TWE031E13FB1 Installer's Manual

Convertible variable speed – air handlers 2 1/2 - 5 ton

Advertisement

Installer's Guide
Convertible Variable Speed -
Air Handlers 2 1/2 - 5 Ton
TWE031E13FB; TWE037E13FB;
TWE040E13FB; TWE049E13FB;
TWE065E13FB
WARNING:
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT - This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
A. GENERAL INFORMATION
WARNING
!
THIS INFORMATION IS FOR USE BY INDIVIDUALS HAVING
ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANI-
CAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL
AIR CONDITIONING PRODUCT MAY RESULT IN PER-
SONAL INJURY AND/OR PROPERTY DAMAGE. THE MANU-
FACTURER OR SELLER CANNOT BE RESPONSIBLE FOR
THE INTERPRETATION OF THIS INFORMATION, NOR CAN
IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE.
CAUTION
!
To prevent shortening its service life, the air handler should
not be used during the finishing phases of construction. The
low return air temperatures can lead to the formation of con-
densate. Condensate in the presence of chlorides and fluo-
rides from paint, varnish, stains, adhesives, cleaning com-
pounds, and cement creates a corrosive condition which may
cause rapid deterioration of the cabinet and internal compo-
nents.
These instructions do not cover all variations in systems or
provide for every possible contingency. Should further in-
formation be desired or particular problems arise which
are not covered sufficiently by this manual, contact your
local distributor or the manufacturer as listed on the air
handler nameplate.
These Air Handlers are shipped from the factory in the
upflow or horizontal right configuration and are fully con-
vertible to downflow or horizontal left. Refer to Section B
beginning on page 3 for additional information.
INSPECTION
Check carefully for any shipping damage. This must be re-
ported to and claims made against the transportation com-
pany immediately. Check to be sure all major components
are in the unit. Any missing parts should be reported to
your supplier at once, and replaced with authorized parts
only.
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
Contents
General Information .............................................. 1
Installation Limitations & Recommendations ............................ 1
Unit Installation ...................................................... 3
Vertical Upflow ......................................................................... 3
Vertical Downflow .................................................................... 3
Horizontal Left .......................................................................... 4
Horizontal Right ....................................................................... 4
Refrigerant Piping ................................................. 5
Condensate Drain Piping ...................................... 6
Electrical - Wiring ................................................... 7
Airflow Adjustment ................................................. 9
Hook Up Diagrams ................................................. 8
Outline Drawings ................................................. 10
Checkout Procedures .......................................... 12
INSTALLATION LIMITATIONS & RECOMMENDATIONS
The general location of the air handler is normally se-
lected by the architect, contractor and/or home owner for
the most effective application and satisfaction.
These air handlers are suitable for installation in a
closet, alcove or utility room with free, non-ducted, air
return, using the area space as a return air plenum.
With ducted supply air, if the minimum clearances to
combustible materials and service access are observed,
the above installations are suitable.
NOTE: Condensation may occur on the
surface of the air handler when installed in
an unconditioned location. When units
are installed in unconditioned spaces,
verify that all electrical and refrigerant line
penetrations on the air handler are sealed
completely.
This area may also be used for other purposes, includ-
ing an electric hot water heater - but in no case shall
18-GE01D1-9

Advertisement

Table of Contents
loading

Summary of Contents for Trane TWE031E13FB1

  • Page 1: Table Of Contents

    Installer’s Guide 18-GE01D1-9 Convertible Variable Speed – Air Handlers 2 1/2 - 5 Ton TWE031E13FB; TWE037E13FB; TWE040E13FB; TWE049E13FB; TWE065E13FB WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT —...
  • Page 2 Installer’s Guide a fossil fuel device be installed and/or operated in tible flooring an accessory sub-base (TAYBASE101 the same closet, alcove or utility room. TWE031E, TAYBASE100 TWE037E, TAYBASE102 for TWE040- 065E) must be used. See In addition, these air handlers are suitable for installa- Figure 1.
  • Page 3: Unit Installation

    Installer’s Guide screws holding the two brackets at the top of the coil. WITHOUT IF AIRHANDLER IS USED A FACTORY FURNISHED b. Remove the factory installed baffle assembly SUPPLEMENTARY HEATER, A PLATE IS REQUIRED TO COVER THE OPEN HOLE IN THE AIR FLOW SYSTEM from the apex of the coil by removing the 5/16"...
  • Page 4: Horizontal Left

    Installer’s Guide HORIZONTAL LEFT the coil channel supports. The tray is detached by removing the two screws at the drain pan and a. For maximum efficiency and Customer ease of the two screws holding the two brackets at the filter maintenance, it is recommended that a prop- erly sized remote filter and grille be installed top of the coil.
  • Page 5: Refrigerant Piping

    Installer’s Guide face velocity of the filter being used. The factory BRAZE SHIELD installed filter should then be removed from the unit. b. Unit is shipped from the factory in the upflow or horizontal right configuration. Unit conversion is not required. c.
  • Page 6: Condensate Drain Piping

    Installer’s Guide F. CONDENSATE DRAIN PIPING NOTE: Make certain that the unit has been installed in a level position to ensure proper draining. 3/4" NPT Secondary drain connection WARNING TO PREVENT INJURY OR DEATH DUE TO ELECTRICAL 3/4" NPT Primary SHOCK OR CONTACT WITH MOVING PARTS, LOCK drain connection UNIT DISCONNECT SWITCH IN OPEN POSITION...
  • Page 7: Electrical - Wiring

    Installer’s Guide It is always recommended that an auxiliary drain pan 3. Field wiring diagrams for electric heaters and unit be installed under a horizontally installed air handler. accessories are shipped with the accessory. Connect the auxiliary drain line to a separate drain line 4.
  • Page 8: Hook Up Diagrams

    Installer’s Guide TWE-E AIR HANDLERS WITH SINGLE STAGE COOLING, 2 STAGE HEAT From Dwg. No. B801074 TWE-E AIR HANDLERS WITH TWO STAGE COOLING, 2 STAGE HEAT 18-GE01D1-9...
  • Page 9: Airflow Adjustment

    Installer’s Guide TWE-E AIR HANDLERS WITH SINGLE STAGE HEAT PUMP From Dwg. No. B801077 H. CONTROL WIRING type electrical connectors are provided for use with 1. Connect wiring between indoor unit, outdoor unit and supplementary heaters. thermostat. The use of color-coded low-voltage wires is IMPORTANT: recommended.
  • Page 10: Outline Drawings

    OUTLINE DRAWING FOR TWE031, 037, 040, 049 & 065E13F DISCHARGE DISCHARGE OPENING OPENING TOP VIEW AIRFLOW FIGURE 1 FIGURE 2 FIG. 1 FIG. 2 MODEL NO. TWE031E13 19.22 18.22 TWE037E13 21.22 20.22 SIDE VIEW 12.02 11.02 TWE040E13 TWE049E13 23.72 22.72 TWE065E13 VERTICAL UPFLOW RETURN...
  • Page 11 Installer’s Guide CAGE NUT MOUNTING LOCATION FOR TWE AIR HANDLERS 1.50 3.70 19.50 2.50 1.00 FOR TWO PIECE CABINET ONLY. 21.00 Model No. TWE031E13 43.00 21.50 17.00 39.00 TWE037E13 45.00 23.50 19.00 41.00 TWE040E13 51.75 23.80 47.75 TWE049E13 57.90 26.00 29.00 53.90 TWE065E13...
  • Page 12: Checkout Procedures

    Blower speed changes are made on the ICM Fan Con- Switches 1 - 4 Cooling Airflow trol mounted on the control box. The ICM Fan Control Switches 5 - 6 Fan Off Delay Options controls the variable speed motor. Switches 7 - 8 Auxiliary Heat There is a bank of 8 dip switches (See Figure 9).