Mitsubishi Electric MELSEC iQ-F Manual page 41

Fx5 positioning module function block reference
Hide thumbs Also See for MELSEC iQ-F:
Table of Contents

Advertisement

No.
Variable name
Name
(13)
o_uAbsErrId
ABS error code
(14)
o_bErr
Error completion
(15)
o_uErrId
Error code
FB details
Item
Description
Available device
Target module
Target CPU
Engineering tool
Language
Ladder diagram
Number of basic steps
225 steps
The number of FB steps integrated in the program varies depending on the CPU module used, the input/output definition, and
the setting options of GX Works3. For the setting options of GX Works3, refer to GX Works3 Operating Manual.
Processing
• By turning on i_bEN (Execution command), the absolute position is restored.
• When the absolute position restoration is completed with an error, o_bAbsNG (ABS error) turns on and an error code is
stored in o_uAbsErrId (ABS error code). For the error codes, refer to MELSEC iQ-F FX5 User's Manual (Positioning
Control - Intelligent function module).
• If the setting value of the target axis is out of the setting range, o_bErr (Error completion) turns on and the processing of this
FB is interrupted. In addition, the error code 100 (hexadecimal) is stored in o_uErrId (Error code). For the error code, refer to
Page 41 Error code.
FB compilation method
Macro type
FB operation
Pulsed execution (multiple scan execution type)
Data type
Default value
Word [Unsigned]
0
Bit
OFF
Word [Unsigned]
0
FX5-20PG-P
FX5U CPU, FX5UC CPU
GX Works3 Version 1.035M or later
Description
The error code of the absolute position restoration
instruction is stored.
For the error codes, refer to MELSEC iQ-F FX5
User's Manual (Positioning Control - Intelligent function
module).
When this label is ON, it indicates that an error has
occurred in the FB.
Stores the error code that occurred in the FB.
2 POSITIONING MODULE FB
2.12 M+FX5PG_ABRST
2
39