2.13

M+FX5PG_StartAddressOffsetPositioning

Name
M+FX5PG_StartAddressOffsetPositioning
Overview
Item
Overview
Symbol
Labels
■Input label
No.
Variable name
(1)
i_bEN
(2)
i_stModule
(3)
i_uPrecedingAxis
(4)
i_uFollowingAxis
(5)
i_uStartBlock
(6)
i_uPoint
(7)
i_bShape
(8)
i_uStartDataNo
(9)
i_uParameter
(10)
i_dOffsetAddress
2 POSITIONING MODULE FB
42
2.13 M+FX5PG_StartAddressOffsetPositioning
Description
The following axis starts after the preceding axis has started and moved the set movement amount.
M+FX5PG_StartAddresOffsetPositioning
(1)
B
:
i_bEN
(2)
DUT
:
i_stModule
(3)
UW
:
i_uPrecedingAxis
(4)
UW : i_uFollowingAxis
(5)
UW
:
i_uStartBlock
(6)
UW
:
i_uPoint
(7)
B : i_bShape
(8)
UW : i_uStartDataNo
(9)
UW
:
i_uParameter
(10)
D
:
i_dOffsetAddress
Name
Data type
Execution command
Bit
Module label
Structure
Preceding axis
Word [Unsigned]
Following axis
Word [Unsigned]
Start block
Word [Unsigned]
Point
Word [Unsigned]
Da.11: Shape
Bit
Da.12: Start data No.
Word [Unsigned]
Da.14: Parameter
Word [Unsigned]
(condition data No.)
Offset address
Double word
[Signed]
o_bENO
:
B
(11)
o_bOK
:
B
(12)
o_bErr
:
B
(13)
o_uErrId
:
UW
(14)
Range
Description
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
The setting range
Specifies the module label for the positioning module.
differs depending on
the module label.
1 to 4
Specify the number of the preceding axis.
The setting range varies according to the positioning
module in use.
1 to 4
Specify the number of the following axis.
The setting range varies according to the positioning
module in use.
0 to 4
Specify the start block.
0: Start block 0
1: Start block 1
2: Start block 2
3: Start block 3
4: Start block 4
1 to 50
Specify the point number.
ON, OFF
Set the shape.
OFF: End
ON: Continuous
1 to 600
Set the "positioning data No." specified with the "block
starting data".
1 to 10
Set the condition data No.
-2147483648 to
Set the start timing offset movement amount.
2147483647
(When the preceding axis Pr. 1: unit setting is 2: degree
-35999999 to 35999999)