Air Conditioning, Refrigeration and Electrical practices and have sound knowledge of current Industrial Safe Working practices. These units consist of 600E/M cassettes using remote wired controllers, 600 L cassettes using infrared controllers and 600 E cassettes using infrared controllers.
Page 3
Heronhill - for all your Marstair requirements PART NUMBERS Fascia 55222000 (all models) Fitted with 0.5m lift pump Fitted with 5m condensate pump 600E/M model Part number 55222001 55222002 55222003 55222004 55222005 55222006 600L model part number 55222007 55222008 55222009...
Page 4
Air Conditioning Systems Heat Pump Systems 600 (ALL) MCU+ or DCU+ 600L / 600E MHPUL / MHPUE / DHPUE NOTE: Table above is for 600 units matched with Marstair outdoor units. 4/25 55208033-08 Tel: 01823 665660 www.heronhill.co.uk Fax: 018123 665807...
Heronhill - for all your Marstair requirements PERFORMANCE DATA (kW) NOTE THAT THERE ARE 3 SPEED RANGES OF LOW, MEDIUM AND HIGH Range 3 = highest for maxium duties Range 2 = medium for normal operations Range 1 = lowest for minimum noise levels...
Page 6
Heronhill - for all your Marstair requirements AIRFLOWS RANGE 3 LOW SPEED MEDIUM SPEED HIGH SPEED RANGE 2 LOW SPEED MEDIUM SPEED HIGH SPEED RANGE 1 LOW SPEED MEDIUM SPEED HIGH SPEED 600 (ALL) 0.12 0.146 0.173 0.209 0.256 0.12 0.146...
Heronhill - for all your Marstair requirements BRANCH DUCT The graphs below show the amount of conditioned air passed by a single branch duct. FAN SPEED RANGE 1 FOR MINIMUM NOISE LEVELS FAN SPEED RANGE 2 FOR NORMAL NOISE LEVELS...
Heronhill - for all your Marstair requirements ELECTRICAL DATA Cooling data rated at EUROVENT (NEMA) conditions 27°C / 19.4°C indoor; 35°/24°C ambient. Heating data rated at 20°C/12°C indoor; 7°C/6°C ambient With MCU+ 1 Ph 230V 50Hz 3 Ph 400V 50Hz...
Page 9
Heronhill - for all your Marstair requirements ELECTRICAL LOADS [ 230V 50Hz 1Ph (A) OR 400V 50Hz 3PhN (A/Ph)] 600 (ALL) FAN MOTOR LIFT PUMP (10 watts) CONDENSATE PUMP (27.6 watts) 12.5mA 12.5mA 12.5mA ELECTRIC HEATER (1kW) ELECTRIC HEATER (2Kw)
Heronhill - for all your Marstair requirements REMOTE CONTROLLER Changeover Changeover Fan control is between activated 1K in heating temperature Frost normal when contact mode, 0.5K in dependent in protection operation and of switch is cooling mode all operating disabled...
Page 14
Heronhill - for all your Marstair requirements 14/25 55208033-08 Tel: 01823 665660 www.heronhill.co.uk Fax: 018123 665807...
Heronhill - for all your Marstair requirements FAN SPEED SELECTION HIGH MEDIUM Factory Settings INTERCONNECTING WIRING POWER - TO SUIT SUPPLY FUSE SIGNAL - 230 V (0.75 - 2.5 mm²) SIGNAL - 230 V ( - 2.5 mm²) INTERNAL 1Ph MCU+ / DCU+...
Page 16
Heronhill - for all your Marstair requirements 1Ø MHPUE / DHPUE 1Ø DCU+ / MCU+ PCBA DATA FUSED SUPPLY (230V 1Ø 50Hz) FUSED SUPPLY (230V 1Ø 50Hz) 600E 600E OR INDEPENDENT FUSED SUPPLY DATA 3Ø MHPUE / DHPUE 3Ø DCU+/ MCU+...
Page 18
Heronhill - for all your Marstair requirements REINSTALLING THE CHASSIS 600E/M 600 L & 600 E FITTING THE FASCIA ☺ ☺ ☺ D I 4 F C F D 600E/M 600 L 600 E 18/25 55208033-08 Tel: 01823 665660 www.heronhill.co.uk...
Heronhill - for all your Marstair requirements USER MAINTENANCE ISOLATE THE UNIT ELECTRICALLY BEFORE COMMENCING ANY WORK We recommend that in order to maintain maximum efficiency of this unit, it’s important that the filter behind the return air grille is cleaned regularly.
Heronhill - for all your Marstair requirements FAULT FINDING CONDITION POSSIBLE CAUSE ACTION Check fuse rating and replace if necessary. Check Indoor fan motor will not run No electric supply at socket or switched fuse box for loose electrical connections...
Page 22
Heronhill - for all your Marstair requirements SPECIFIC FAULT DIAGNOSIS FOR L UNITS CONDITION POSSIBLE CAUSE ACTION Check for alarms LEDs flashing - see table below If NO external connections are made to alarm terminal 5, the presence of an alarm condition can be tested for by checking for mains voltage at terminal 5;...
Page 23
Heronhill - for all your Marstair requirements SPECIFIC FAULT DIAGNOSIS FOR E UNITS A fully electronic system comprising 600 E with MHPUE or DCUE communicates between the units by digital codes. Signals are transmitted every 10 seconds, therefore a delay of up to 10 seconds could occur before the system responds to a command. Similarly if the communication link is broken, the outdoor unit will shut down within 15 seconds.
Heronhill - for all your Marstair requirements COMPONENT IDENTIFICATION CHASSIS ASSEMBLY Top panel Suspension bracket Capacitor Fan motor 5m condensate pump 5m condensate pump PCB and filter Heat exchanger Coil blanking panel Electric box cover External electrics box Chassis Fresh air cover...
Page 25
Heronhill - for all your Marstair requirements FASCIA ASSEMBLY LED lens/cover Vane bearing Fascia Vane connector Grille Vane motor Filter Double yoke Badge Spider Air deflector vane Actuator arm Vane end cap TEL: FAX: TEV LTD, ARMYTAGE ROAD, BRIGHOUSE, WEST YORKSHIRE, HD6 1QF.
Need help?
Do you have a question about the 600E/M and is the answer not in the manual?
Questions and answers