Special installation (Installed facing upward)
(2) When the Plasma Display is in a confined space
Operating this display in confined spaces is not recommended.
• If the display is to be used in confined spaces, observe the following conditions shown in the drawing below:
A ≥ 50
• If heat remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the
inner wall should have sufficient heat resistance or fire resistance.
• Leave a space at least 10 mm wide when installing glass etc. on the front of the Plasma Display.
✩ Usage temperature conditions
• Ambient temperature: 0 °C to 35 °C (Outside air temperature)
• Space enclosed by the back surface of the Plasma Display: 0 °C to 35 °C (Use a fan etc. to discharge air to
maintain this temperature range.)
*1
For this installation, set the 'FAN CONTROL' to 'MAX' as shown in "5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting" (pg. 235).
: Thermometer (temperature measurement point)
Note
When installing the Plasma Display facing upwards, do not place anything on top of it nor apply any load on it from
above.
52
(*1)
Outside air temperature
measuring point
50 mm
Enclosed space air temperature
measuring point
Outside air
temperature
measuring point
A
A ≥ 50
[507CMX]
Enclosed space air
temperature measuring
point
10 mm