[507CMX]

3.5.8 Installed facing upward

(1) When installed on top of a horizontal surface <an open space other than a horizontal surface>
50 mm or more
✩ Operating Temperature Restrictions
• Ambient temperature: 0 °C to 35 °C
• The same operating temperature restrictions apply to the speaker system (PDP-S53-LR).
*1
For this installation, set the 'FAN CONTROL' to 'MAX' as shown in "5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting" (pg. 235).
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
Before attaching the unit to fittings, double-check that the thickness and height of the fittings
and the number of bolts is correct.
(Also refer to "3.5.1 Mounting to fittings" (pg. 35).)
Special Installation (Installed facing upward)
Horizontal surface
(*1)
. The methods indicated by a large "X" must not be used.
Installation is not possible