Garmin GIA 63 Installation Manual page 113

Hide thumbs Also See for GIA 63:
Table of Contents

Advertisement

4.7.2.3 To/From
Pin Name
VOR/LOC +TO
VOR/LOC +FROM (VOR/LOC COMMON)
VOR/LOC +FROM (NAV COMMON)
(011-01105-2X/-3X/-4X ONLY)
The output is capable of driving up to three 200 Ω meter loads. When indicating TO, the output is
+225 ±75 mVDC. When indicating FROM, output is -225 ±75 mVDC. When invalid information is
present (Flag IN VIEW) the TO/FROM output is 0 ±10 mVDC.
4.7.2.4 Flag
Pin Name
VOR/LOC +FLAG
VOR/LOC -FLAG (VOR/LOC COMMON)
VOR/LOC -FLAG (NAV COMMON)
(011-01105-2X/-3X/-4X ONLY)
GLIDESLOPE +FLAG
GLIDESLOPE -FLAG (GLIDESLOPE COMMON)
GLIDESLOPE –FLAG (NAV COMMON)
(011-01105-2X/-3X/-4X ONLY)
The Flag output is capable of driving up to three 1000 Ω meter loads. When valid information is present
(Flag OUT OF VIEW) the Flag output is 375 ±80 mVDC. When invalid information is present (Flag IN
VIEW) the Flag output is 0 ±25 mVDC.
190-00303-05
Rev. Y
Table 4-25. To/From
Table 4-26. Flag
Connector
Pin
P602
1
P602
2
Connector
Pin
P602
3
P602
4
P602
32
P602
53
GIA 63 Installation Manual
I/O
Out
Out
I/O
Out
Out
Out
Out
Page 4-29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents