Port Specific and Communications Protocol SIS Commands

Symbol definitions
X6)
= Password
NOTE:
The HTML language reserves certain characters for specific functions (see
X6!
= A 2- to 6-digit time zone code, such as "
X6@
= UTC offset and location name, such as
X6#
= IP address
X6$
= Prefix (subnet mask bits). Default subnet mask 255.255.00.000 is represented as a prefix value as /16.
X6%
= Port number
X6^
= Baud rate
X6&
= Parity
X6*
= Data bits
X6(
= Stop bits
X6%
X6(
NOTE:
through
and
X4(
through
for the RS-232 inserts.
X7)
= Flow control (use only the first letter)
X7!
= Data pacing between bytes
X7@
= Wait time for characters arriving at a serial port before terminating
X7#
= Wait time between characters before terminating
X7$
= Priority status for receiving timeouts
X7%
NOTE:
is an optional parameter.
X7%
= Parameter to set either length or delimiter
X7^
= Verbose mode
NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command
does (for example, the read matrix name command
X7&
= Port timeout interval (in 10-second increments)
Up to 128 characters, all characters valid with the exception of pipe (|)
" for GMT - 8.00
PST
(UTC-08:00) Pacific Time
###.###.###.###
= Remote (RS-232) port
01
9600
(default),
odd, even, none, mark, space (only the first letter required) (n = default)
7
,
8
(default)
(default),
1
X7&
are variables for the rear panel Remote RS-232 port. These variables are repeated on page 57 as
Hardware, Software, None (only the first letter required) (N = default)
0000 – 1000 (in milliseconds, default = 0 ms). (For a host port, this value is ignored
and returns 0.)
0 – 32767 (in 10s of milliseconds, default is 10 = 100 ms). Commands using both
X7@
and
0 – 32767 (in 10s of milliseconds, default is 2 = 20 ms). Commands using both
X7@
and
Most users do not use this variable, included for response only (see the
0 = use send data string command parameters (if they exist) (default)
1 = use configure receive timeout command parameters
Most users do not use this variable, included for response only (see the
Lnnnnn = length of message to receive (nnnnn = 0 – 32767, default = 0L
Dnnnnn = decimal value for ASCII character (0 – 00255, default=00000D).
The parameter is case sensitive (D or L). The response is returned with leading 0s.
= Clear or none (default for Telnet connection)
0
= Verbose mode (default for RS-232 or USB connection)
1
= Tagged responses for queries
2
= Verbose mode and tagged for queries
3
E
}
CN
1
(= 10 seconds) -
DTP CrossPoint 4K Series Matrix Switchers • Programming Guide
Special Characters
for
PST
19200
,
38400
,
115200
2
X7#
must have both values set to 0 or both set to non-zero.
X7#
must have both values set to 0 or both set to non-zero.
X2$]
, returns
).
Ipn
65000
(default is
30
= 300 seconds = 5 minutes)
on page 84).
X4$
NOTE
on page 83).
NOTE
on page 83).
82