CNI2 Operating and Installation Guide
Boost Capacitor
Connects to the TB1 terminal block and assists the battery pack during peak current events,
usually during radio transmission.
Low-Voltage Detector
Measured at the TB1, J1 and J2 power connectors, which ever has the highest voltage. A user-
selectable alarm point in the range of 0.1 – 28 Vdc can be used to report low-voltage situations.
Power Input #3 (TB1) Connector Type
Screw terminal, 5.08 mm (0.2") spacing. 90º entry. 14-26 AWG (0.14 – 1.5 mm) wire size.
Maximum torque is 0.6 Nm (5.3 lbs.-in). See next illustration for polarity.
Power Input #1 & #2 (J1 and J2) Connector Type
3-pin JST B3B-XH-A. Recommended mating connector is JST XHP-3 connector housing with
two SXH-001T-P0.6 female contacts. See next illustration for polarity.
Power Input Connector Polarities
154