Control Testing Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
"Quick Test" Mode for M1 Electronic Range Control (ERC)
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1. Press and hold CANCEL and BROIL pads for 3 to 5 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
Pressing the pad once activates the response.
NOTE:
Press the pad a second time deactivates the response.
This mode must be entered within the first 5 minutes of power up.
NOTE:
If the temperature sensor reaches 400° F, the Quick Test mode will be disabled.
NOTE:
Display will indicate the following:
Key
[Bake]
[Broil]
[Keep Warm]
[Cook&Hold]
[Clean]
[Delay] (M1)
[Timer]
[Clock]
[More +]
[Less –]
[Cancel]
Description of Error Codes
Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode.
Each error code is four digits long and is created based on the following table.
Digit
st
1
nd
2
rd
3
th
4
Diagnostic Code Display Mode can be activated by pressing and holding the AUTOSET pad for 3 to 5 seconds at
power-up. Diagnostic Code Display Mode can only be started while powering up the control.
May 2006
© 2006 Maytag Services
!
Bake relay activated
Broil relay activated
N\A
Last Diagnostic Code displayed
MDL relay activated (lock and unlock)
EEPROM Version Number displayed
Main Code Version Number displayed
All Segments On
Even Segments On
Odd Segments On
End Factory Test Mode
Primary System:
1 – Local to the control circuit board
3 – Sensor or meat probe
4 – Control input
9 – Door lock
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
Secondary System: Sequential numbering
Oven Cavity:
1 – Upper oven (or single cavity oven)
2 – Lower oven
c – Control specific
WARNING
Operation
Description
5
16027222
Replaces 16022499